Autor: |
Maria, Gerogiannaki-Christopoulou, Nikolaos V, Kyriakidis, Panagiotis E, Athanasopoulos |
Rok vydání: |
2004 |
Předmět: |
|
Zdroj: |
Journal of AOAC International. 86(6) |
ISSN: |
1060-3271 |
Popis: |
A study of the correlation between the refractive index (RI) method adopted by the European Community (EC) and a reference pycnometric method for the measurement of alcoholic strength was undertaken. A new RI method with greater accuracy was also developed. Alcoholic strength measured by both RI methods presented a relatively constant negative bias compared with results by the pycnometric method. Differences found between the RI methods and the pycnometric method were 0.6-0.9% (v/v) when RI was measured by the EC method and 0.4-0.5% (v/v) when the new RI method developed in our laboratory was used. Statistical analysis of the results showed that differences between the 2 RI methods and the reference pycnometric method were statistically significant at the 95% confidence level. Correction factors are proposed for the accurate use of measurements of alcoholic strength obtained for small volume samples. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|