Stability and impurity profiling are in high demand to guarantee the potency, safety and efficacy of new formulations along with their shelf-life. In this study, stability testing of alfuzosin (ALF) and solifenacin (SOL) in their newly co-formulated capsules was conducted under different stress conditions. The obtained degradation products were structurally elucidated and found to be their official impurities, namely; ALF impurity-D and SOL impurities-A, EI. A selective and reliable stability-indicating HPLC method was developed for assaying the cited drugs along with three of those official impurities. Chromatographic separation was accomplished within 8 minutes using a XBridge® C18 column as the stationary phase and acetonitrile : phosphate buffer (pH 8) : triethylamine (60 : 40 : 0.02, by volume) as the mobile phase at a flow rate of 1.3 mL min-1. Quantification of the analytes was performed at 210 nm using a diode array detector through which peak purity was assessed. The proposed method was validated as per ICH guidelines and it was successfully applied for the determination of the cited drugs in their combined pharmaceutical formulation with percent recoveries of 100.47 and 100.15 for ALF and SOL, respectively. Moreover, the proposed method was exploited for the assessment of the two drugs' stability in Solitral® capsules under accelerated storage conditions. The method was further extended for studying the degradation kinetics of the two drugs. |