Preparation of restricted access monolithic tip via unidirectional freezing and atom transfer radical polymerization for directly extracting magnolol and honokiol from rat plasma followed by liquid chromatography analysis
Autor: | Hongwu Zhang, Yaoyao Hu, Jingwei Zhou, Peichun Chen |
---|---|
Rok vydání: | 2020 |
Předmět: |
Honokiol
Quality Control Monolithic HPLC column Infrared spectroscopy 010402 general chemistry 01 natural sciences Biochemistry High-performance liquid chromatography Lignans Analytical Chemistry Polyethylene Glycols chemistry.chemical_compound Freezing Animals Solid phase extraction Chromatography High Pressure Liquid Chromatography Atom-transfer radical-polymerization 010401 analytical chemistry Organic Chemistry Biphenyl Compounds Solid Phase Extraction Pipette Reproducibility of Results General Medicine Magnolol 0104 chemical sciences Rats chemistry Methacrylates Hydrophobic and Hydrophilic Interactions |
Zdroj: | Journal of chromatography. A. 1625 |
ISSN: | 1873-3778 |
Popis: | In the present study, a novel strategy based on unidirectional freezing and atom transfer radical polymerization combined with activator regenerated by electron transfer (ARGET-ATRP) was applied to synthesizing orderly macroporous monolithic column with restricted-access (RA) property in a 1000μL pipette tip. The RA column was composed of hydrophobic inner column (poly(styrene-co-ethylene glycol dimethacrylate) and hydrophilic outer layer (poly-hydroxyethyl methacrylate chain) which was grafted on the hydrophobic surface by means of the second ARGET-ATRP reaction. The as-prepared RA monolithic tip was connected to a 2mL syringe for directly extracting magnolol and honokiol from rat plasma just by manually pushing operation. The surface morphology and chemical composition of the column were characterized by scanning electronic microscope, infrared spectroscopy and X-ray photoelectron spectroscopy respectively. The determined results of evaluation experiments based on the optimized solid phase extraction conditions showed that the RA column possessed good protein exclusion power, extraction recovery and reusability. The constructed RA-SPE-HPLC/UV method for simultaneously analyzing magnolol and honokiol in rat plasma was validated with quality control (QC) samples at four concentration levels. Good precision (RSDs, 3.39~11.16%) and acceptable accuracy (relative recoveries, 89.52%~108.42%) were obtained for intra- and inter-day assays. The determined results of real rat plasma as well as the standard-addition samples demonstrated the developed method with good accuracy and precision. It can be extrapolated from the experimental results that this simple and cost-efficient RA-SPE method is also suitable for directly extracting other hydrophobic constituents in biological body fluid for therapeutic drug monitoring or pharmacokinetic study. |
Databáze: | OpenAIRE |
Externí odkaz: |