Evaluation of dynamic headspace with gas chromatography/mass spectrometry for the determination of 1,1,1-trichloroethane, trichloroethanol, and trichloroacetic acid in biological samples

Autor: Russell L. Dills, Douglas O. Johns, Michael S. Morgan
Rok vydání: 2005
Předmět:
Zdroj: Journal of Chromatography B. 817:255-261
ISSN: 1570-0232
DOI: 10.1016/j.jchromb.2004.12.013
Popis: A sensitive and reproducible method is described for the analysis of trichloroacetic acid in urine and 1,1,1-trichloroethane in blood using dynamic headspace GC/MS. Samples were analyzed using the soil module of a modified purge and trap autosampler to facilitate the use of disposable purging vessels. Coefficients of variation were below 3.5% for both analytes, and response was linear in the range of 0.01-7.0 microg/ml for trichloroacetic acid and 0.9 ng/ml-2.2 microg/ml for 1,1,1-trichloroethane. Attempts at using dynamic headspace for the analysis of trichloroethanol in urine were unsuccessful.
Databáze: OpenAIRE