Soft tissue attenuation patterns in stress myocardial perfusion SPECT images: a comparison between supine and upright acquisition systems

Autor: David Chawla, Amit P. Amin, Rami Doukky, Hector X. Martinez, Tareq Alyousef, Mouyyad Rahaby, Raj Vashistha
Rok vydání: 2010
Předmět:
Zdroj: Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 18(2)
ISSN: 1532-6551
Popis: Soft tissue attenuation patterns and their interaction with body habitus and gender in Single Photon Emission Computed Tomography (SPECT)-myocardial perfusion imaging (MPI) of upright patient-position acquisition systems are not well described. In a retrospective cross-sectional study, we compared the prevalence and patterns of soft tissue attenuation in two groups of normal SPECT-MPI studies acquired by supine (n = 263) vs upright (n = 212) acquisition systems. Attenuation patterns observed in the study population were: anterior (22.3%), inferior (51.6%) and lateral (18.1%). Anterior attenuation was significantly less in those imaged upright (6.1% vs 35.4%), P
Databáze: OpenAIRE