Early Weight-Bearing after Statically Locked Reamed Intramedullary Nailing of Comminuted Femoral Fractures: Is It a Safe Procedure?
Autor: | Abdurrahman Kutlu, Tunç Cevat Öğün, Recep Memik, Mehmet Arazi, M. Oktar |
---|---|
Rok vydání: | 2001 |
Předmět: |
Adult
Male medicine.medical_specialty Time Factors Adolescent Rotation Bone Screws Dentistry Bone healing medicine.disease_cause law.invention Weight-bearing Weight-Bearing Intramedullary rod Risk Factors law Fracture fixation medicine Humans Femur Range of Motion Articular Early Ambulation Fractures Comminuted Aged Fracture Healing business.industry Implant failure Middle Aged Fracture Fixation Intramedullary Prosthesis Failure Surgery Radiography Treatment Outcome Orthopedic surgery Female Safety Range of motion business Femoral Fractures Follow-Up Studies |
Zdroj: | The Journal of Trauma: Injury, Infection, and Critical Care. 50:711-716 |
ISSN: | 1079-6061 |
Popis: | Background The purpose of this study was to determine the safety of early weight-bearing after statically locked reamed nailing of comminuted fractures of the femoral diaphysis, and to assess the rate of implant failure and fracture healing. Methods Thirty consecutive patients with comminuted diaphyseal femur fractures (Winquist type II, III, and IV) were treated with statically locked reamed intramedullary nailing. Six patients were lost to follow-up, and the remaining 24 patients were followed at least 1 year. Early weight-bearing was allowed and encouraged in the first 2 weeks after the operation. The nail diameters were 13 mm in 16 patients, 12 mm in 6 patients, and 14 mm in 2 patients. Results Most of the patients could start weight-bearing between the first 2 and 4 weeks postoperatively. None of the patients, except one, were using any walking aids at the second month postoperatively. All the fractures healed without any significant complications. Nail bending or breakage did not occur in any patients, but there was slight bending in one distal interlocking screw and one proximal interlocking screw. The fractures of the patients with bent screws healed uneventfully. Conclusion This study showed that early weight-bearing after reamed static interlocking nailing of Winquist type II, III, and IV femoral fractures is a safe and effective method, and the risk of implant failure does not preclude the procedure. |
Databáze: | OpenAIRE |
Externí odkaz: |