Retention force of differently fabricated telescopic PEEK crowns with different tapers
Autor: | Christina Wagner, Susanne Merk, Malgorzata Roos, Bogna Stawarczyk, Patrick R. Schmidlin, Marlis Eichberger, Veronika Stock |
---|---|
Přispěvatelé: | University of Zurich, Stawarczyk, Bogna |
Rok vydání: | 2016 |
Předmět: |
Dental Stress Analysis
Fabrication Materials science Pellets 610 Medicine & health 2503 Ceramics and Composites 02 engineering and technology Dental Prosthesis Retention 03 medical and health sciences 0302 clinical medicine Fabrication methods 10066 Clinic of Conservative and Preventive Dentistry Pellet Peek Humans Composite material General Dentistry Crowns 10060 Epidemiology Biostatistics and Prevention Institute (EBPI) 030206 dentistry 021001 nanoscience & nanotechnology 3500 General Dentistry Ceramics and Composites 0210 nano-technology |
Zdroj: | Dental Materials Journal. 35:594-600 |
ISSN: | 1881-1361 0287-4547 |
Popis: | To assess the retention force between primary and secondary PEEK crowns made by different fabrication methods. Primary crowns with different tapers (0°, 1°, and 2°) were fabricated and secondary crowns that were either milled from breCam BioHPP blanks, pressed from pellets (BioHPP Pellet) or granules (BioHPP Granulat) were produced. Each specimen was measured 20 times in a pulloff-test and results were analyzed using 2-/1-way ANOVA and linear regression analyses (p |
Databáze: | OpenAIRE |