Influence of the auxiliary air-duct outlet and the brattice location on the methane hazard-numerical simulations

Autor: Pavel Zapletal, Grzegorz Pach, Zenon Różański, Dariusz Musioł, Paweł Wrona, Adam Niewiadomski, Marian Sofranko
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Energies; Volume 15; Issue 10; Pages: 3672
Popis: The article presents the results of research into the influence of the location of auxiliary ventilation devices on the distribution of methane concentrations at the outlet of the longwall in an underground mine. Since this area is crucial from the point of view of explosion risk, the existence of an optimal arrangement of these devices could lead to improved safety of the crew working in the area. The aim of conducted study was to examine if the impact of this devices placement is significant. The research was carried out with the use of computational fluid dynamics (CFD) modeling-Ansys Fluent. The analyses took into account the location of the two most commonly used devices: a brattice and an auxiliary air-duct. The numerical model has been prepared and validated based on in situ measurements. Thirty-two cases of device configurations were analysed. The length and position of the brattice, as well as the height and position air-duct outlet along tailgate, were modified. It has been shown that although the presented solutions are an effective risk mitigation method, contrary to the common opinion of many practitioners, the impact of their exact placement, provided it is compliant with the regulations, is not significant for the registered methane concentration distribution at a longwall outlet. Web of Science 15 10 art. no. 3672
Databáze: OpenAIRE