Privacy friendly aggregation of smart meter readings, even when meters crash
Autor: | Jaap-Henk Hoepman |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2017 |
Předmět: |
Engineering
Smart meter Smart meters Crash 02 engineering and technology Basic protocols Smart grid Computer security computer.software_genre Meter readings Set (abstract data type) Electric power transmission networks CSR - Cyber Security & Robustness Smart power grids 0202 electrical engineering electronic engineering information engineering Metre Crash failures Protocol (science) Privacy friendly aggregation TS - Technical Sciences business.industry Aggregate (data warehouse) Fault tolerance 020206 networking & telecommunications Lower bounds Consensus protocols ICT Digital Security Privacy problems business computer |
Zdroj: | 2nd Workshop on Cyber-Physical Security and Resilience in Smart Grids, CPSR-SG 2017. 21 April 2017, 3-7 CPSR-SG'17: Proceedings of the 2nd Workshop on Cyber-Physical Security and Resilience in Smart Grids, Pittsburgh, PA, USA — April 18-21, 2017, pp. 3-7 CPSR-SG'17: Proceedings of the 2nd Workshop on Cyber-Physical Security and Resilience in Smart Grids, Pittsburgh, PA, USA — April 18-21, 2017, 3-7. New york : ACM STARTPAGE=3;ENDPAGE=7;TITLE=CPSR-SG'17: Proceedings of the 2nd Workshop on Cyber-Physical Security and Resilience in Smart Grids, Pittsburgh, PA, USA — April 18-21, 2017 SPSR-SG@CPSWeek |
Popis: | A well studied privacy problem in the area of smart grids is the question of how to aggregate the sum of a set of smart meter readings in a privacy friendly manner, i.e., in such a way that individual meter readings are not revealed to the adversary. Much less well studied is how to deal with arbitrary meter crashes during such aggregation protocols: current privacy friendly aggregation protocols cannot deal with these type of failures. Such failures do happen in practice, though. We therefore propose two privacy friendly aggregation protocols that tolerate such crash failures, up to a predefined maximum number of smart meters. The basic protocol tolerates meter crashes at the start of each aggregation round only. The full, more complex, protocol tolerates meter crashes at arbitrary moments during an aggregation round. It runs in a constant number of phases, cleverly avoiding the otherwise applicable consensus protocol lower bound. ACM Special Interest Group on Embedded Systems (SIGBED); IEEE CS; IEEE Signal Processing Society |
Databáze: | OpenAIRE |
Externí odkaz: |