Graphitic carbon nitride as sorbent for the emulsification-enhanced disposable pipette extraction of eight organochlorine pesticides prior to GC-MS analysis
Autor: | Sze Chieh Tan, Hian Kee Lee |
---|---|
Rok vydání: | 2019 |
Předmět: |
Detection limit
Sorbent Chromatography 010401 analytical chemistry Extraction (chemistry) Graphitic carbon nitride 02 engineering and technology 021001 nanoscience & nanotechnology 01 natural sciences 0104 chemical sciences Analytical Chemistry Matrix (chemical analysis) chemistry.chemical_compound chemistry Elemental analysis Sample preparation Gas chromatography–mass spectrometry 0210 nano-technology |
Zdroj: | Mikrochimica acta. 187(2) |
ISSN: | 1436-5073 |
Popis: | Graphitic carbon nitride (g-C3N4) was explored as a sorbent for the emulsification-enhanced (EE) disposable pipette extraction (DPX) of eight organochlorine pesticides (OCPs) from environmental waters. The OCPs, including α-hexachlorocyclohexane, Aldrin, α-Chlordane, Dieldrin, 4,4′-dichlorodiphenyldichloroethylene, 4,4′-dichlorodiphenyldichloroethane, Heptachlor and Heptachlor epoxide (Isomer A), were analyzed by gas chromatography-mass spectrometry. The sorbent g-C3N4 was characterized by elemental analysis, X-ray diffraction, scanning electron microscopy, Fourier-transform infrared and Raman spectroscopy. As a C-N analogue of graphite, g-C3N4 exhibits good water dispersibility and allows easy analyte recovery – a characteristic not commonly observed in carbon-based materials. When applied to DPX, g-C3N4 rapidly establishes strong interactions with the OCPs. Consequently, g-C3N4 displays superior extraction capability in comparison to six other commercial sorbents. An emulsification step prior to DPX was found to enhance the overall extraction efficiency by pre-concentrating the OCPs into the microdroplets of an organic solvent. The microdroplets were then adsorbed onto g-C3N4. Under the most favorable conditions, wide linear responses spanning over two to four orders of magnitudes are established. The limits of detection range between 2.4 ng·L−1 and 46.2 ng·L−1. The method is reproducible (relative standard deviations ≤ 7.4%) and enrichment factors are between 42 and 57. When applied to the analysis of lake and river water samples, EE-DPX-gas chromatography-mass spectrometry exhibits good resilience against matrix interferences. The relative recoveries range between 77.7% and 106.3%. In comparison to other sorbent-based extraction techniques reported for the analysis of OCPs in aqueous samples, EE-DPX utilizes the minimal amount of sample and solvent, and requires the shortest sample preparation time. |
Databáze: | OpenAIRE |
Externí odkaz: |