Operational Performance of an AnaerobicAnoxic-Aerobic Treatment System

Autor: Paulo Eduardo Vieira Cunha, André Luis Calado Araújo, Danilo Luiz de Magalhães Ferraz, Fernando José Araújo da Silva, Cícero Fernandes Neto
Rok vydání: 2017
Předmět:
Zdroj: Fronteiras: Journal of Social, Technological and Environmental Science, Vol 6, Iss 3, Pp 247-263 (2017)
ISSN: 2238-8869
DOI: 10.21664/2238-8869.2017v6i3.p247-263
Popis: An anaerobic (UASB) – hybrid aerobic (suspended and attached growth activated sludge) wastewater treatment system was evaluated on the removal of organic matter, solids and nitrogen following its pre-operational phase. Analysis were made weekly based on composite samples, prepared by grab samples taken every four hours, during 24-hour cycle, weighted by flow rate, on each monitoring point (raw sewage, UASB, anoxic chamber, aerobic reactors, return sludge from secondary decanters and final effluent). The plant presented an average flow rate of 908 m3/h with peaks from 10 to 14 h. BOD was removed by 86 % (310 to 41 mg/L) being the highest parcel accounted by UASB reactors (70 %) and removal of total suspended solids reached 63 % (190 to 94 mg/L). Mean removals of TKN (71 %) and Ammonium (77 %) were above the value predicted by design and, probably the nitrification-denitrification process was not the dominant route.
Databáze: OpenAIRE