Experimental Studies of Energy Systems of Automatic Control Heat Supply of Residential Buildings and Methods of Increasing Their Efficiency
Autor: | Kodkin, V.L., Anikin, A.S., Baldenkov, A.A., Kachalin, A.Yu. |
---|---|
Rok vydání: | 2017 |
Předmět: |
Engineering
Automatic control business.industry Heat carrier Heat supply Boiler (power generation) Environmental engineering УДК 658.512 General Medicine Coolant flow optimization of heating system УДК 658.012.01.56 УДК 658.264 coolant flow энергоэффективность зданий расход теплоносителя energy efficiency of buildings оптимизация тепловых систем business Process engineering 662.92 [УДК 620.9] Efficient energy use |
Zdroj: | Bulletin of the South Ural State University. Ser. Computer Technologies, Automatic Control & Radioelectronics. 17:156-161 |
ISSN: | 2409-6571 1991-976X |
DOI: | 10.14529/ctcr170215 |
Popis: | Кодкин Владимир Львович, д-р техн. наук, профессор кафедры автоматизированного электропривода, Южно-Уральский государственный университет, г. Челябинск; kodkina2@mail.ru. Аникин Александр Сергеевич, доцент кафедры теоретических основ электротехники, Южно- Уральский государственный университет, г. Челябинск; anikinsasha@gmail.ru. Балденков Александр Александрович, аспирант кафедры автоматизированного электропривода, Южно-Уральский государственный университет, г. Челябинск; baloo@mail.ru. Качалин Андрей Юрьевич, аспирант кафедры автоматизированного электропривода, Южно-Уральский государственный университет, г. Челябинск; kachalin89@inbox.ru. V.L. Kodkin, kodkina2@mail.ru, A.S. Anikin, anikinsasha@gmail.ru, A.A. Baldenkov, baloo@mail.ru, A.Y. Kachalin, kachalin89@inbox.ru South Ural State University, Chelyabinsk, Russian Federation Results of trial operation of system of heat supply of the residential building with the optimized processes of regulation of temperature of the heat carrier are given in article. The actual indicators of volumes of the consumed gas for several months 2015 and values of temperature of external air are analyzed. It is shown that “factory” settings of controllers don't ensure effective functioning, especially at temperatures of external air close to 0 °С. The data, which showed that the optimization of processes in heating systems developed techniques for increasing their efficiency by 10–15 %. On the basis of pilot studies in a suburban boiler room with considerable losses in a heating main, the method of increase in their energy efficiency by increase in giving of the heat carrier is offered. The method is realized by means of the converter of frequency installed for control of the network pump. The experiments have confirmed efficiency of the offer. Приведены результаты опытной эксплуатации системы теплоснабжения жилого здания с оптимизированными процессами регулирования температуры теплоносителя. Проанализированы фактические показатели объемов потребленного газа за несколько месяцев 2015 года и значения температуры наружного воздуха в это же время. Показано, что заводские настройки регуляторов не обеспечивают эффективной работы, особенно при температурах наружного воздуха, близких к 0 °С. Приведены данные, показавшие, что оптимизация процессов в системах отопления по разработанным методикам повышают их эффективность на10–15 %. На основе экспериментальных исследований в пригородной котельной со значительными потерями в теплотрассе, предложен метод повышения их энергоэффективности путем увеличения подачи теплоносителя. Метод реализован с помощью преобразователя частоты, установленного для управления сетевым насосом, и эксперименты подтвердили эффективность предложения. |
Databáze: | OpenAIRE |
Externí odkaz: |