Autor: |
Rie Sakai-Bizmark, Ruey-Kang R. Chang, Gerard R. Martin, Lisa A. Hom, Emily H. Marr, Jamie Ko, Donna A. Goff, Laurie A. Mena, Connie von Kohler, Lauren E. M. Bedel, Mary Murillo, Dennys Estevez, Ron D. Hays |
Rok vydání: |
2022 |
Předmět: |
|
Zdroj: |
American journal of perinatology. |
ISSN: |
1098-8785 |
Popis: |
Objective Our objective was to gauge adherence to nationally endorsed protocols in implementation of pulse oximetry (POx) screening for critical congenital heart disease (CCHD) in infants after mandate by all states and to assess associated characteristics. Study Design Between March and October 2019, an online questionnaire was administered to nurse supervisors who oversee personnel conducting POx screening. The questionnaire used eight questions regarding performance and interpretation of screening protocols to measure policy consistency, which is adherence to nationally endorsed protocols for POx screening developed by professional medical societies. Multilevel linear regression models evaluated associations between policy consistency and characteristics of hospitals and individuals, state of hospital location, early versus late mandate adopters, and state reporting requirements. Results Responses from 189 nurse supervisors spanning 38 states were analyzed. Only 17% received maximum points indicating full policy consistency, and 24% selected all four options for potential hypoxia that require a repeat screen. Notably, 33% did not recognize ≤90% SpO2 as an immediate failed screen and 31% responded that an infant with SpO2 of 89% in one extremity will be rescreened by nurses in an hour rather than receiving an immediate physician referral. Lower policy consistency was associated with lack of state reporting mandates (beta = –1.23 p = 0.01) and early adoption by states (beta = –1.01, p Conclusion When presented with SpO2 screening values on a questionnaire, a low percentage of nurse supervisors selected responses that demonstrated adherence to nationally endorsed protocols for CCHD screening. Most notably, almost one-third of respondents did not recognize ≤90% SpO2 as a failed screen that requires immediate physician follow-up. In addition, states without reporting mandates and early adopter states were associated with low policy consistency. Implementing state reporting requirements might increase policy consistency, but some inconsistency may be the result of unique protocols in early adopter states that differ from nationally endorsed protocols. Key Points |
Databáze: |
OpenAIRE |
Externí odkaz: |
|