Rapid and specific detection of Enterococcus faecalis with a visualized isothermal amplification method

Autor: Zhu, Bo, Hu, Juan, Li, Xuelian, Li, Xiaomin, Wang, Lei, Fan, Shihui, Jin, Xin, Wang, Kun, Zhao, Weiguo, Zhu, Wenjun, Chen, Cheng, Wang, Zilu, Lu, Yingzhi
Rok vydání: 2022
Předmět:
Zdroj: Frontiers in Cellular and Infection Microbiology. 12
ISSN: 2235-2988
DOI: 10.3389/fcimb.2022.991849
Popis: Enterococcus faecalis is a serious problem for hospitals and can spread from patient to patient. Most of the current detection methods are associated with limitations associated with the need for trained personnel; they are also time-consuming. Thus, it is necessary to develop rapid and accurate detection methods to control the spread of E. faecalis. In this study, we developed a rapid and accurate detection method for E. faecalis using recombinase polymerase amplification (RPA) combined with a lateral flow strip (LFS). This method could be completed in approximately 35 min at 37°C. The limit of detection was 10 CFU/µL, irrespective of whether the templates were pure or complex. This method also showed good specificity and compatibility. In total, 278 clinical samples were tested using the RPA-LFS method; the detection accuracy was equal to that of the conventional qPCR method. This visualized isothermal amplification method could be useful for the future on-site detection of E. faecalis.