Pararectal Migration of a Malleable Rod: An Unusual Late Complication

Autor: Salih Polat, İbrahim Küçüktürkmen, Ibrahim Halil Bozkurt, Ozgu Aydogdu, Yusuf Kadir Topçu, Serkan Yarimoglu, Tansu Degirmenci
Rok vydání: 2016
Předmět:
Zdroj: The World Journal of Men's Health
The World Journal of Men's Health, Vol 34, Iss 2, Pp 145-147 (2016)
ISSN: 2287-4208
Popis: A 75-year-old male had failed to respond conservative therapy for erectile dysfunction and had undergone insertion of a malleable penile prosthesis in 1995. Twenty years after the initial implant he presented with right-sided prosthesis localized in the buttock. There was no infection. The prosthesis was extracted through an incision in the right hip. As in the recent case, mechanical failures in malleable penile prosthesis models, can occur. Penile implant migration back to the buttock without a curve deformity is an extremely rare complication. Clinicians should be alert about possible late complications of penile prosthesis.