Bridging the Analytical Gap Between Gas Treatment and Reactor Plants in Carbon2Chem®

Autor: Hegen, O., Gómez, J., Grünwald, C., Rettke, A., Sojka, M., Klucken, C., Pickenbrock, J., Filipp, J., Schlögl, R., Ruland, H.
Rok vydání: 2022
Předmět:
Zdroj: Chemie-Ingenieur-Technik
ISSN: 1522-2640
0009-286X
DOI: 10.1002/cite.202200015
Popis: The use of purified process gases as feedstock for subsequent processes requires a detailed verification of the gas purity to ensure long lifetimes of applied catalysts. Herein, the analytical infrastructure for the measurements of the cleaned gases is presented. An overview of all sampling points for the off- and on-line analysis is given. The detailed decryption of the composition of the cleaned blast furnace gas, its main components as well as its traces are presented. Thereby, over 99 % of the overall signal strength of this complex gas matrix measured with a proton transfer reaction mass spectrometer with H3O+ as reagent ion could be revealed. Furthermore, by the example of the catalyst poison H2S, the necessity of monitoring continuously the gas matrix for certain compounds was proven.
Databáze: OpenAIRE