Determination of oxeladin in human plasma by gas chromatography—mass spectrometry

Autor: C. Lartigue-Mattei, J L Chabard, J. M. Aiache, M. J. Galmier, E. Beyssac
Rok vydání: 1995
Předmět:
Zdroj: Biomedical Chromatography. 9:32-35
ISSN: 1099-0801
0269-3879
DOI: 10.1002/bmc.1130090107
Popis: A capillary gas chromatographic method with mass-selective detection was developed for the determination of oxeladin in human plasma. Plasma samples (1 mL) were alkalinized and extracted using 5mL of hexane: isoamyl alcohol (99:1). The method was demonstrated to be sensitive (limit of quantitation at 1 ng/mL), linear between 1 and 150 mg/mL, accurate and precise enough (mean error and mean coefficient of variation at the limit of quantitation were 2.3 and 13.3%, respectively) to support pharmacokinetic evaluation of the drug at doses down to 30 mg.