Ultrasonic shears and bipolar vessel-sealing system for three-port laparoscopic ovariohysterectomy in dogs
Autor: | Maurício Veloso Brun, N. Guizzo-Júnior, L.W. Sartori, Rogério Luizari Guedes, M.C. Bairros, Marco Augusto Machado Silva, Gustavo Brambatti, Fabiane Reginatto dos Santos, Adriana Costa da Motta, J.P.S. Feranti, F.V. Tomazzoni, M. Bortoluzzi |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2015 |
Předmět: |
medicine.medical_specialty
medicine.medical_treatment Uterus laparoscopy laparoscopia surgery caninos Port (medical) medicine Statistical analysis spay canines Laparoscopy sistemas de coagulação cirurgia lcsh:SF1-1100 Hysterectomy General Veterinary medicine.diagnostic_test business.industry Vessel sealing castração Surgery medicine.anatomical_structure coagulation systems Hemostasis Ultrasonic sensor lcsh:Animal culture business |
Zdroj: | Arquivo Brasileiro de Medicina Veterinária e Zootecnia, Vol 67, Iss 1, Pp 55-61 (2015) Arquivo Brasileiro de Medicina Veterinária e Zootecnia, Volume: 67, Issue: 1, Pages: 55-61, Published: FEB 2015 Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.67 n.1 2015 Arquivo brasileiro de medicina veterinária e zootecnia Universidade Federal de Minas Gerais (UFMG) instacron:UFMG |
ISSN: | 1678-4162 |
Popis: | In the current experimental study, two different instruments were compared for prophylactic hemostasis during a 3-port technique of laparoscopic ovariohysterectomy (OVH) in bitches. Moreover, the need for port enlargement for specimen retrieval using 5mm or 10mm trocartes, technical difficulties and complications were assessed. Ultrasonic energy and a vascular sealing system were tested. Duration of surgery, patient weight and diameter of the uterine arteries and veins were compared among the groups. Fifteen dogs randomly divided into three groups (GI, GII, GIII) were submitted to ovariohysterectomy with hemostasis from the use of ultrasonic scalpel or vascular sealing equipment. In GI and GII the LigaSure(tm)impedance-controlled bipolar vessel-sealing device was used, differing in the size of trocartes used between groups, and in GIII Autosonix(tm) was used. Patients' weight, duration of surgery, technical difficulties and complications were compared among the groups. Statistical analysis showed no difference between the data analyzed among the groups. In conclusion, both methods of hemostasis were effective for 3-port total laparoscopic ovariohysterectomy in bitches. However, 5mm trocartes were not adequate for retrieval of the uterus and ovaries without need for enlargement of the port incision. No presente experimento, foram comparados dois diferentes equipamentos, um com emprego de energia ultrassônica, e outro utilizando sistema de selamento vascular, como única forma de hemostasia em ovário-histerectomias laparoscópicas com três portais em cadelas. Ademais, a necessidade de ampliação da incisão do portal de 5mm ou de 10mm para a remoção dos espécimes ressecados, dificuldades técnicas e complicações foram avaliadas. Quinze cadelas aleatoriamente distribuídas em três grupos (GI, GII, GIII) foram submetidas à ovário-histerectomia com hemostasia a partir da utilização de bisturi ultrassônico ou equipamento de selamento vascular. Nos GI e GII foi utilizado um sistema de selamento vascular eletrotérmico bipolar (LigaSure(r)), diferindo-se no tamanho dos portais utilizados; em GIII foi utilizado bisturi ultrassônico (Autosonix(r)). A análise estatística não demonstrou diferença significativa entre os dados analisados nos três grupos. Conclui-se que ambos os métodos de hemostasia utilizados mostraram-se adequados e viabilizaram a realização de ovário-histerectomia laparoscópica em cadelas. Todavia, o trocarte de 5mm não foi adequado para remoção do útero e ovários sem necessidade de ampliação da incisão de acesso. |
Databáze: | OpenAIRE |
Externí odkaz: |