Use of a Tap Extractor to Remove a Broken Tap within a Grosse-Kempf Intrameduallary Nail

Autor: Stephen J. Ruff, Andrew K. Cree
Rok vydání: 1995
Předmět:
Zdroj: The Journal of Trauma: Injury, Infection, and Critical Care. 38:802-803
ISSN: 1079-6061
DOI: 10.1097/00005373-199505000-00021
Popis: A tap extractor was used to dislodge a broken tap that prevented removal of an intramedullary nail. This was imperative because of metal incompatibility and corrosion. Correct use of extraction equipment should allow atraumatic retrieval of intramedullary fixation. The proper technique for retapping a thread in an intramedullary nail is described.
Databáze: OpenAIRE