ALINHAMENTO RADIOGRÁFICO DA COLUNA VERTEBRAL CERVICAL EM UMA AMOSTRA DE INDIVÍDUOS ASSINTOMÁTICOS
Autor: | Mohamed Ahmed Nasreddine, Raphael de Rezende Pratali, Carlos Eduardo Gonçales Barsotti, Carlos Eduardo Algaves Soares de Oliveira, Francisco Prado Eugenio dos Santos |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2017 |
Předmět: |
Spinal curvatures
lcsh:Diseases of the musculoskeletal system Cervical vertebrae Curvaturas de la columna vertebral Asymptomatic 03 medical and health sciences 0302 clinical medicine lcsh:Orthopedic surgery Medicine Orthopedics and Sports Medicine 030212 general & internal medicine Curvaturas da coluna vertebral Coluna vertebral business.industry Vértebras cervicais Cervical spine Spine Columna vertebral Radiography lcsh:RD701-811 Radiografia Surgery Neurology (clinical) medicine.symptom lcsh:RC925-935 Radiografía business Nuclear medicine Vértebras cervicales 030217 neurology & neurosurgery |
Zdroj: | Coluna/Columna v.16 n.1 2017 Coluna/Columna Sociedade Brasileira de Coluna (SBCO) instacron:SBCO Coluna/Columna, Volume: 16, Issue: 1, Pages: 13-16, Published: JAN 2017 Coluna/Columna, Vol 16, Iss 1, Pp 13-16 |
Popis: | Objective: To present normality parameters for the cervical spine in a sample of the Brazilian population and its distribution by sex and age. Methods: This was a prospective study considering 94 asymptomatic individuals evaluated by panoramic radiograph of the spine for the analysis of the following parameters: cervical lordosis (CL), C2 sagittal vertical axis (SVA-C2), cervical sagittal vertical axis (cSVA), and T1 Slope (TA-T1). The parameter values were compared according to sex and age of individuals. Results: The mean CL was -16.5° (SD: ± 10.8°), SVA-C2 was -3.9 mm (SD: ± 29.2 mm), cSVA was 16.9 mm (SD: ± 10.6 mm) and TA-T1 was 24.8° (SD: ± 7.0°). There was no significant difference between the radiographic parameters when considered with respect to sex and age of individuals (P>0.05). The analysis of correlation among the radiographic parameters showed that the TA-T1 presented the highest correlation with the other parameters, including CL (r= 0.367, P0,05). A análise da correlação entre os parâmetros radiográficos demonstrou que o AI-T1 apresentou a maior correlação com os demais parâmetros, incluindo LC (r= 0,367, P 0,05). El análisis de la correlación entre los parámetros radiográficos mostró que el AI-T1 presentó la mayor correlación con los otros parámetros, incluyendo LC (r= 0,367, P |
Databáze: | OpenAIRE |
Externí odkaz: |