CHARACTERISING THE EOS SLOT-SCANNING SYSTEM WITH THE EFFECTIVE DETECTIVE QUANTUM EFFICIENCY

Autor: Jean Michel Létang, P. Monnin, F. R. Verdun, A. H. Clavel, A. Darbon
Přispěvatelé: Imagerie Tomographique et Radiothérapie, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (CREATIS), Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon), Institut National des Sciences Appliquées (INSA)-Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université de Lyon-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon), Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM), Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université Claude Bernard Lyon 1 (UCBL)
Rok vydání: 2015
Předmět:
Transducers
Radiation
Radiation Dosage
Sensitivity and Specificity
Imaging phantom
030218 nuclear medicine & medical imaging
Labex PRIMES
Detective quantum efficiency
03 medical and health sciences
Kerma
0302 clinical medicine
Optics
Imaging
Three-Dimensional

categₛt2i
[INFO.INFO-IM]Computer Science [cs]/Medical Imaging
Figure of merit
Radiology
Nuclear Medicine and imaging

Imagerie tomographique et thérapie par rayonnement
Physics
Radiological and Ultrasound Technology
business.industry
Phantoms
Imaging

Detector
Public Health
Environmental and Occupational Health

Reproducibility of Results
General Medicine
Equipment Design
Equipment Failure Analysis
Radiographic Image Enhancement
030220 oncology & carcinogenesis
Radiographic Image Interpretation
Computer-Assisted

Tomography
business
Tomography
X-Ray Computed

Beam (structure)
Zdroj: Radiation Protection Dosimetry
Radiation Protection Dosimetry, Oxford University Press (OUP), 2015, ⟨10.1093/rpd/ncv451⟩
ISSN: 1742-3406
0144-8420
DOI: 10.1093/rpd/ncv451⟩
Popis: International audience; As opposed to the standard detective quantum efficiency (DQE), effective DQE (eDQE) is a figure of merit that allows comparing the performances of imaging systems in the presence of scatter rejection devices. The geometry of the EOS\texttrademark slot-scanning system is such that the detector is self-collimated and rejects scattered radiation. In this study, the EOS system was characterised using the eDQE in imaging conditions similar to those used in clinical practice: with phantoms of different widths placed in the X-ray beam, for various incident air kerma and tube voltages corresponding to the phantom thickness. Scatter fractions in EOS images were extremely low, around 2 % for all configurations. Maximum eDQE values spanned 9\textendash14.8 % for a large range of air kerma at the detector plane from 0.01 to 1.34 \textmuGy. These figures were obtained with non-optimised EOS setting but still over-performed most of the maximum eDQEs recently assessed for various computed radiology and digital radiology systems with antiscatter grids.