Abnormal Conduction Increases Risk of Adverse Outcomes From Right Ventricular Pacing
Autor: | Peter J. Kudenchuk, Anna O Leonen, John M. Herre, John C. Love, Arjun D. Sharma, David Investigators, John J. Hayes |
---|---|
Jazyk: | angličtina |
Předmět: |
medicine.medical_specialty
Adverse outcomes Heart Ventricles Context (language use) Implantable defibrillator Risk Assessment QRS complex Electrocardiography Heart Conduction System Internal medicine medicine Humans Multicenter Studies as Topic cardiovascular diseases Risk factor Proportional Hazards Models Randomized Controlled Trials as Topic Heart Failure business.industry Cardiac Pacing Artificial medicine.disease Survival Analysis Defibrillators Implantable Heart failure Circulatory system Cardiology Disease Progression business Complication Cardiology and Cardiovascular Medicine |
Zdroj: | Journal of the American College of Cardiology. (8):1628-1633 |
ISSN: | 0735-1097 |
DOI: | 10.1016/j.jacc.2006.05.071 |
Popis: | Objectives The purpose of this study was to determine whether QRS duration or morphology increased the risk of adverse outcome in the DAVID (Dual Chamber and VVI Implantable Defibrillator) trial. Background The DAVID trial found an increased risk of the combined end point of death and new or worsening congestive heart failure (CHF) in defibrillator recipients who were paced DDDR-70 versus VVI-40. Methods We analyzed the combined end point in patients with abnormal QRS duration (AbQRS) (≥110 ms) compared with those with normal QRS duration (NQRS) ( Results The QRS data were available for 496 of the 506 patients enrolled in the trial, including 223 patients with NQRS (45%) and 273 patients with AbQRS (55%). In patients in whom defibrillators were programmed to pace infrequently (VVI-40), having an NQRS or AbQRS was not an indicator of increased risk of adverse outcome. However, among patients in whom defibrillators were programmed in a manner that promoted more frequent ventricular pacing (DDDR-70), there was a significant adverse interaction with AbQRS; this combination was independently associated with a higher risk for developing CHF or death (p = 0.017). Conclusions Although patients with AbQRS tended to have other risk factors associated with poor outcome, the interaction of QRS duration with ventricular pacing (DDDR-70) independently contributed to a worse outcome and therefore, was a marker of patients in whom such treatment may be harmful. This should not imply that right ventricular pacing in NQRS patients is safe but rather that pacing in the context of an AbQRS is probably best avoided. |
Databáze: | OpenAIRE |
Externí odkaz: |