Evaluation of a novel monoclonal antibody‐based enzyme immunoassay for detection of Histoplasma antigen in urine of dogs
Autor: | Andrew S Hanzlicek, Kristen Clark |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.medical_specialty
Antigens Fungal 040301 veterinary sciences medicine.drug_class Histoplasma canine Infectious Disease Standard Article Urine 030204 cardiovascular system & hematology invasive fungal infection Monoclonal antibody Sensitivity and Specificity Gastroenterology Histoplasmosis Immunoenzyme Techniques 0403 veterinary science 03 medical and health sciences Dogs 0302 clinical medicine Antigen Disseminated histoplasmosis Internal medicine medicine Animals Prospective Studies mycoses Mycosis General Veterinary medicine.diagnostic_test biology business.industry mycosis Antibodies Monoclonal 04 agricultural and veterinary sciences medicine.disease biology.organism_classification Standard Articles fungal Immunoassay mycology SMALL ANIMAL business |
Zdroj: | Journal of Veterinary Internal Medicine |
ISSN: | 1939-1676 0891-6640 |
Popis: | Background Commercially available, noninvasive testing options for histoplasmosis are limited outside of the United States. Objectives To describe the diagnostic performance of a novel Histoplasma antigen enzyme immunoassay (IM EIA) for the diagnosis of histoplasmosis in dogs. Animals Twenty dogs with histoplasmosis, 79 dogs without histoplasmosis, and 11 unclassified dogs providing 202 urine samples. Methods This a prospective study using stored urine samples. Samples were analyzed with the IM EIA and with the commercially available Histoplasma antigen EIA (MV EIA). Dogs were classified based on final proven diagnosis and performance of the IM EIA was described and compared with the MiraVista enzyme immunoassay (MV EIA). Results The diagnostic sensitivity (DSe), specificity (DSp), and accuracy (DAc) of the IM EIA were 70% (51%-89%), 99% (97%-100%), and 93% (81%-100%), respectively. The DSe, DSp, and DAc for the MV EIA were 95% (85%-100%), 99% (97%-100%), and 98% (95%-100%), respectively. The area under the receiver operator characteristic curve was significantly smaller for IM EIA (0.87) as compared with MV EIA (0.97, P = .03). This was primarily due to 6 false negative IM EIA results, 4 from dogs with disease localized to the gastrointestinal tract. The MV EIA was positive in 5/6 of these dogs. Conclusions and clinical importance The IM EIA might be useful for the diagnosis of disseminated histoplasmosis in dogs, but clinical usefulness will be limited in dogs with histoplasmosis localized to the GI tract. |
Databáze: | OpenAIRE |
Externí odkaz: |