Aortic Regurgitation Generates a Kinematic Obstruction Which Hinders Left Ventricular Filling
Autor: | Ajit P. Yoganathan, Vrishank Raghav, Ikechukwu Okafor, Gautam Kumar, Prem A. Midha, Jose F. Condado |
---|---|
Rok vydání: | 2017 |
Předmět: |
Aortic valve
medicine.medical_specialty Swine Heart Ventricles Aortic Valve Insufficiency Biomedical Engineering Diastole Kinematics Regurgitation (circulation) 030204 cardiovascular system & hematology Ventricular Outflow Obstruction 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine Mitral valve Internal medicine medicine Animals Physics Jet (fluid) Models Cardiovascular Biomechanical Phenomena medicine.anatomical_structure Particle image velocimetry Ventricle Cardiology Blood Flow Velocity |
Zdroj: | Annals of Biomedical Engineering. 45:1305-1314 |
ISSN: | 1573-9686 0090-6964 |
DOI: | 10.1007/s10439-017-1790-z |
Popis: | An incompetent aortic valve (AV) results in aortic regurgitation (AR), where retrograde flow of blood into the left ventricle (LV) is observed. In this work, we parametrically characterized the detailed changes in intra-ventricular flow during diastole as a result of AR in a physiological in vitro left-heart simulator (LHS). The loss of energy within the LV as the level of AR increased was also assessed. The validated LHS consisted of an optically-clear, flexible wall LV and a modular AV holder. Two-component, planar, digital particle image velocimetry was used to visualize and quantify intra-ventricular flow. A large coherent vortical structure which engulfed the whole LV was observed under control conditions. In the cases with AR, the regurgitant jet was observed to generate a “kinematic obstruction” between the mitral valve and the LV apex, preventing the trans-mitral jet from generating a coherent vortical structure. The regurgitant jet was also observed to impinge on the inferolateral wall of the LV. Energy dissipation rate (EDR) for no, trace, mild, and moderate AR were found to be 1.15, 2.26, 3.56, and 5.99 W/m3, respectively. This study has, for the first time, performed an in vitro characterization of intra-ventricular flow in the presence of AR. Mechanistically, the formation of a “kinematic obstruction” appears to be the cause of the increased EDR (a metric quantifiable in vivo) during AR. EDR increases non-linearly with AR fraction and could potentially be used as a metric to grade severity of AR and develop clinical interventional timing strategies for patients. |
Databáze: | OpenAIRE |
Externí odkaz: |