APPLICATION OF APNEIC OXYGENATION IN TRACHEAL SURGERY
Autor: | Lavrinenko Vy, Titov Va, Alekseev Av, Bunyatyan Aa, Vyzhigina Ma, Vladimir Parshin |
---|---|
Rok vydání: | 2018 |
Předmět: |
Hemodynamics
030204 cardiovascular system & hematology pCO2 Hypercarbia 03 medical and health sciences 0302 clinical medicine medicine Humans Acidosis Intraoperative Care business.industry Pulmonary Gas Exchange Oxygenation respiratory system Carbon Dioxide Respiration Artificial Tracheal Stenosis Oxygen Anesthesiology and Pain Medicine 030220 oncology & carcinogenesis Anesthesia Emergency Medicine Breathing Arterial blood medicine.symptom Blood Gas Analysis business |
Zdroj: | Anesteziologiia i reanimatologiia. 62(1) |
ISSN: | 0201-7563 |
Popis: | BACKGROUND The tracheal surgery is associated with opening of airways and historically used different methods of maintaining gas exchange: System "shunt-breathing", the injection ventilation, high frequency jet ventilation and even artificial circulation. In recent years increased the interest of use of apneic oxygenation (A 0). THE AIM to study the impact ofthe application ofA o on the gas exchange, acid-base balance of arterial blood, in patients undergoing reconstructive surgery on the trachea and bronchi with AO. MATERIALS AND METHODS The study included 130 patients with stenotic disease of the trachea, operated in the period from 2011 to 2014 usingAO. RESULTS Application ofAO provides a high level of oxygenation and is accompanied by a moderate increase in pCO2 level and the development of acidosis. Hypercarbia and acidosis were not accompanied with hemodynamic disturbances on ECG, heart rate and invasive measurement of blood pressure at high values of Pa O₂. |
Databáze: | OpenAIRE |
Externí odkaz: |