Lung Ventilation and Perfusion in Prone and Supine Postures with Reference to Anesthetized and Mechanically Ventilated Healthy Volunteers
Autor: | Sven Nyrén, Margareta Mure, Hans Jacobsson, Sten G. E. Lindahl, Stig A. Larsson, Alejandro Sanchez-Crespo, Peter J. Radell, Johan Petersson |
---|---|
Rok vydání: | 2010 |
Předmět: |
Adult
Male Pulmonary Circulation Supine position business.operation medicine.medical_treatment Anesthesia General Single-photon emission computed tomography Prone Position Supine Position medicine Humans Oximetry Lung Sodium Pertechnetate Tc 99m Tomography Emission-Computed Single-Photon Mechanical ventilation medicine.diagnostic_test business.industry Indium Radioisotopes Environmental air flow Mallinckrodt Respiration Artificial Oxygen Prone position Anesthesiology and Pain Medicine Anesthesia Respiratory Mechanics Breathing Female Radiopharmaceuticals Nuclear medicine business Perfusion |
Zdroj: | Anesthesiology. 112:682-687 |
ISSN: | 0003-3022 |
DOI: | 10.1097/aln.0b013e3181cf40c8 |
Popis: | Background The literature on ventilation (V) and lung perfusion (Q) distributions during general anesthesia and controlled mechanical ventilation in supine and prone position is contradictory. The authors aimed to investigate whether V, Q, and ventilation to perfusion ratio (V/Q ratio) matching in anesthetized and mechanically ventilated volunteers are gravity dependent irrespective of posture. Methods Seven healthy volunteers were studied at two different occasions during general anesthesia and controlled mechanical ventilation. One occasion studied ventral to dorsal V and Q distributions in the supine posture and the other in the prone posture. Imaging was performed in supine posture at both occasions. A dual radiotracer technique and single photon emission computed tomography were used. V and Q were simultaneously tagged with Tc-Technegas (Tetley Manufacturing Ltd., Sydney, Australia) and In-labeled macroaggregates of human albumin (TechneScan LyoMAA, Mallinckrodt Medica, Petten, The Netherlands), respectively. Results No differences in V between postures were observed. Q differed between postures, being more uniform over different lung regions in prone posture and dependent in supine posture. The contribution of the vertical direction to the total V/Q ratio heterogeneity was larger in supine (31.4%) than in prone (16.4%) (P = 0.0639, two-tailed, paired t test) posture. Conclusions During mechanical ventilation, prone posture favors a more evenly distributed Q between lung regions. V distribution is independent of posture. This results in a tendency toward lower V/Q gradients in the ventral to dorsal direction in prone compared with supine posture. |
Databáze: | OpenAIRE |
Externí odkaz: |