Initial stability of a percutaneous osseointegrated endoprosthesis with proximal interlocking screws for transhumeral amputees
Autor: | Kent N. Bachus, Robert Z. Tashjian, Peter N. Chalmers, Alex J. Drew, Heath B. Henninger, Carolyn E. Taylor |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Male
medicine.medical_treatment Population Bone Screws Biophysics Osseointegration Article 03 medical and health sciences 0302 clinical medicine Amputees Cadaver medicine Ultimate failure Humans Orthopedics and Sports Medicine Humerus education Mechanical Phenomena Orthodontics education.field_of_study business.industry 030229 sport sciences Initial stability equipment and supplies musculoskeletal system Biomechanical Phenomena medicine.anatomical_structure surgical procedures operative Amputation Female Implant business Bone Plates 030217 neurology & neurosurgery |
Zdroj: | Clin Biomech (Bristol, Avon) |
Popis: | Background Percutaneous osseointegrated devices for skeletal fixation of prosthetic limbs have the potential to improve clinical outcomes in the transhumeral amputee population. Initial endoprosthesis stability is paramount for long-term osseointegration and safe clinical introduction of this technology. We evaluated an endoprosthetic design featuring a distally porous coated titanium stem with proximal slots for placement of bicortical interlocking screws. Methods Yield load, ultimate failure load, and construct stiffness were measured in 18 pairs of fresh-frozen and thawed cadaver humeri, at distal and proximal amputation levels, without and with screws, under axial pull-out, torsion, and bending loads. Paired statistical comparisons were performed without screws at the two resection levels, and at distal and proximal levels with and without screws. Findings Without screws, the location of the amputation influenced the stability only in torsional yield (p = 0.032) and torsional ultimate failure (p = 0.033). Proximally, the torsional yield and the torsional ultimate failure were 44% and 47% of that distally. Screws improved stability. In axial pull-out, screws increased the distal ultimate failure 3.2 times (p = 0.003). In torsion, screws increased the yield at the proximal level 1.9 times (p = 0.035), distal ultimate failure load 3.3 times (p = 0.016) and proximal ultimate failure 6.4 times (p = 0.013). In bending, screws increased ultimate failure at the proximal level 1.6 times (p = 0.026). Interpretation Proximal slots and bicortical interlocking screws may find application in percutaneous osseointegrated devices for patients with amputations, especially in the less stable proximal bone of a short residual limb. |
Databáze: | OpenAIRE |
Externí odkaz: |