Correlative mass spectrometry imaging, applying time-of-flight secondary ion mass spectrometry and atmospheric pressure matrix-assisted laser desorption/ionization to a single tissue section
Autor: | Bernhard Spengler, Alain Brunelle, Andreas Römpp, Nicolas Desbenoit, Axel Walch |
---|---|
Přispěvatelé: | Institut für Anorganische und Analytische Chemie, Institut de Chimie des Substances Naturelles (ICSN), Centre National de la Recherche Scientifique (CNRS)-Institut de Chimie du CNRS (INC), Atmospheric Chemistry Department [MPIC], Max Planck Institute for Chemistry (MPIC), Max-Planck-Gesellschaft-Max-Planck-Gesellschaft |
Rok vydání: | 2017 |
Předmět: |
0301 basic medicine
Analytical chemistry Spectrometry Mass Secondary Ion Orbitrap Tandem mass spectrometry Mass spectrometry 01 natural sciences Mass spectrometry imaging Analytical Chemistry law.invention 03 medical and health sciences Nuclear magnetic resonance law [CHIM.ANAL]Chemical Sciences/Analytical chemistry Humans Spectroscopy ComputingMilieux_MISCELLANEOUS Research Articles Chemistry 010401 analytical chemistry Organic Chemistry Histological Techniques Lipids 0104 chemical sciences Secondary ion mass spectrometry Matrix-assisted laser desorption/ionization Time of flight 030104 developmental biology Spectrometry Mass Matrix-Assisted Laser Desorption-Ionization Colonic Neoplasms Mass spectrum Software Research Article |
Zdroj: | Rapid Communications in Mass Spectrometry Rapid Communications in Mass Spectrometry, Wiley, 2018, 32 (2), pp.159-166. ⟨10.1002/rcm.8022⟩ |
ISSN: | 1097-0231 0951-4198 |
DOI: | 10.1002/rcm.8022⟩ |
Popis: | Rationale Mass spectrometry imaging (MSI) is a powerful tool for mapping the surface of a sample. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) offer complementary capabilities. Here, we present a workflow to apply both techniques to a single tissue section and combine the resulting data for the example of human colon cancer tissue. Methods Following cryo-sectioning, images were acquired using the high spatial resolution (1 μm pixel size) provided by TOF-SIMS. The same section was then coated with a para-nitroaniline matrix and images were acquired using AP-MALDI coupled to an Orbitrap mass spectrometer, offering high mass resolution, high mass accuracy and tandem mass spectrometry (MS/MS) capabilities. Datasets provided by both mass spectrometers were converted into the open and vendor-independent imzML file format and processed with the open-source software MSiReader. Results The TOF-SIMS and AP-MALDI mass spectra show strong signals of fatty acids, cholesterol, phosphatidylcholine and sphingomyelin. We showed a high correlation between the fatty acid ions detected with TOF-SIMS in negative ion mode and the phosphatidylcholine ions detected with AP-MALDI in positive ion mode using a similar setting for visualization. Histological staining on the same section allowed the identification of the anatomical structures and their correlation with the ion images. Conclusions This multimodal approach using two MSI platforms shows an excellent complementarity for the localization and identification of lipids. The spatial resolution of both systems is at or close to cellular dimensions, and thus spatial correlation can only be obtained if the same tissue section is analyzed sequentially. Data processing based on imzML allows a real correlation of the imaging datasets provided by these two technologies and opens the way for a more complete molecular view of the anatomical structures of biological tissues. |
Databáze: | OpenAIRE |
Externí odkaz: |