A Modified Technique for Transverse Aortic Constriction in Mice

Autor: Chen Chen, Huihui Li, James Jiqi Wang, Kudusi Abuduwufuer
Rok vydání: 2022
Předmět:
Zdroj: Journal of visualized experiments : JoVE. (186)
ISSN: 1940-087X
Popis: Transverse aortic constriction (TAC) is a frequently used surgery in research regarding heart failure and cardiac hypertrophy based on the formation of pressure overload in mouse models. The main challenge of this procedure is to clearly visualize the transverse aortic arch and precisely band the target vessel. Classical approaches perform a partial thoracotomy to expose the transverse aortic arch. However, it is an open-chest model that causes a rather large surgical trauma and requires a ventilator during the surgery. To prevent unnecessary trauma and simplify the operating procedure, the aortic arch is approached via the proximal proportion of the sternum, reaching and binding the target vessel using a small self-made retractor that contains a snare. This procedure can be conducted without entering the pleura cavity and does not need a ventilator or microsurgical operation, which leaves the mice with physiological breathing patterns, simplifies the procedure, and significantly reduces operation time. Due to the less invasive approach and less operation time, mice can undergo fewer stress reactions and recover rapidly.
Databáze: OpenAIRE