Impact of detecting potentially serious incidental findings during multi-modal imaging
Autor: | Gibson, L, Littlejohns, T, Adamska, L, Garratt, S, Doherty, N, Group, Uk Biobank Imaging Working, Wardlaw, J, Maskell, G, Parker, M, Brownsword, R, Matthews, P, Collins, R, Allen, N, Sellors, J, Sudlow, C |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2017 |
Předmět: |
medicine.medical_specialty
research ethics viruses Medicine (miscellaneous) Methods for Diagnostic & Therapeutic Studies General Biochemistry Genetics and Molecular Biology 030218 nuclear medicine & medical imaging 03 medical and health sciences incidental findings 0302 clinical medicine false positives False positive paradox magnetic resonance imaging Medicine 030212 general & internal medicine Medical diagnosis Protocol (science) Research ethics business.industry false negatives Flagging Public health virus diseases Imaging study Articles medicine.disease Biobank 3. Good health Medical emergency business dual-energy X-ray absorptiometry Research Article |
Zdroj: | Wellcome Open Research |
ISSN: | 2398-502X |
Popis: | Background: There are limited data on the impact of feedback of incidental findings (IFs) from research imaging. We evaluated the impact of UK Biobank’s protocol for handling potentially serious IFs in a multi-modal imaging study of 100,000 participants (radiographer ‘flagging’ with radiologist confirmation of potentially serious IFs) compared with systematic radiologist review of all images. Methods: Brain, cardiac and body magnetic resonance, and dual-energy x-ray absorptiometry scans from the first 1000 imaged UK Biobank participants were independently assessed for potentially serious IFs using both protocols. We surveyed participants with potentially serious IFs and their GPs up to six months after imaging to determine subsequent clinical assessments, final diagnoses, emotional, financial and work or activity impacts. Results: Compared to systematic radiologist review, radiographer flagging resulted in substantially fewer participants with potentially serious IFs (179/1000 [17.9%] versus 18/1000 [1.8%]) and a higher proportion with serious final diagnoses (21/179 [11.7%] versus 5/18 [27.8%]). Radiographer flagging missed 16/21 serious final diagnoses (i.e., false negatives), while systematic radiologist review generated large numbers of non-serious final diagnoses (158/179) (i.e., false positives). Almost all (90%) participants had further clinical assessment (including invasive procedures in similar numbers with serious and non-serious final diagnoses [11 and 12 respectively]), with additional impact on emotional wellbeing (16.9%), finances (8.9%), and work or activities (5.6%). Conclusions: Compared with systematic radiologist review, radiographer flagging missed some serious diagnoses, but avoided adverse impacts for many participants with non-serious diagnoses. While systematic radiologist review may benefit some participants, UK Biobank’s responsibility to avoid both unnecessary harm to larger numbers of participants and burdening of publicly-funded health services suggests that radiographer flagging is a justifiable approach in the UK Biobank imaging study. The potential scale of non-serious final diagnoses raises questions relating to handling IFs in other settings, such as commercial and public health screening. |
Databáze: | OpenAIRE |
Externí odkaz: |