Measurements of surgeons' exposure to ionizing radiation dose: comparison of conventional and mini C-arm fluoroscopy
Autor: | Chin Youb Chung, Eunki Min, Kisung Lee, Ki Hyuk Sung, Byung Chae Jo, Moon Seok Park |
---|---|
Rok vydání: | 2015 |
Předmět: |
Thyroid Gland
Thymus Gland Radiation Radiation Dosage Mini c arm Imaging phantom 030218 nuclear medicine & medical imaging Ionizing radiation 03 medical and health sciences 0302 clinical medicine Occupational Exposure Radiation Ionizing medicine Fluoroscopy Humans Gonads 030222 orthopedics Dosimeter medicine.diagnostic_test Equivalent dose business.industry Phantoms Imaging Dose comparison Radiation Exposure Orthopedics Surgery business Nuclear medicine |
Zdroj: | The Journal of hand surgery, European volume. 41(3) |
ISSN: | 2043-6289 |
Popis: | This study was performed to measure the equivalent scattered radiation dose delivered to susceptible organs while simulating orthopaedic surgery using conventional and mini C-arm fluoroscopy. In addition, shielding effects on the thyroid, thymus, and gonad, and the direct exposure delivered to the patient’s hands were also compared. A conventional and mini C-arms were installed in an operating room, and a hand and an operator phantom were used to simulate a patient’s hand and a surgeon. Photoluminescence dosimeters were used to measure the equivalent dose by scattered radiation arriving at the thyroid, thymus, and gonad on a whole-body phantom in the position of the surgeon. Equivalent scattered radiation doses were measured in four groups: (1) unshielded conventional C-arm group; (2) unshielded mini C-arm group; (3) lead-shielded conventional C-arm group; and (4) lead-shielded mini C-arm group. Equivalent scattered radiation doses to the unshielded group were significantly lower in the mini C-arm group than those in the conventional C-arm group for all organs. The gonad in the lead-shielded conventional C-arm group showed the highest equivalent dose among operator-susceptible organs, and radiation dose was reduced by approximately 96% compared with that in the unshielded group. Scattered radiation was not detected in any susceptible organ in the lead-shielded mini C-arm group. The direct radiation dose to the hand phantom measured from the mini C-arm was significantly lower than that measured from the conventional C-arm. The results show that the equivalent scattered radiation dose to the surgeon’s susceptible organs and the direct radiation dose to a patient’s hand can be decreased significantly by using a mini C-arm rather than a conventional C-arm. However, protective lead garments, such as a thyroid shield and apron, should be applied to minimize radiation exposure to susceptible organs, even during use of mini C-arm fluoroscopy. |
Databáze: | OpenAIRE |
Externí odkaz: |