Preoperative and Intraoperative Considerations Using Intramedullary Nails for the Treatment of Tibial Shaft Fractures Below Total Knee Arthroplasty

Autor: Nicole M. Stevens, Andrew F. Tyler, Phillip M. Mitchell, Daniel J. Stinner
Rok vydání: 2022
Předmět:
Zdroj: Journal of Orthopaedic Trauma. 36:e437-e441
ISSN: 0890-5339
DOI: 10.1097/bot.0000000000002367
Popis: Periprosthetic tibial shaft fractures below total knee arthroplasty (TKA) are relatively rare, with an incidence of approximately 1%. However, as the rates of arthroplasty increase, orthopaedic surgeons are likely to see a corresponding increase in these types of fractures. Native tibial shaft fractures are routinely treated with either nails or plates, and the success of intramedullary nailing of tibial shaft fractures has been well described in the literature. In this article, we seek to describe a case series of tibial shaft fractures in patients with ipsilateral TKA treated with infrapatellar intramedullary nailing. We will focus on preoperative considerations including templating and measurement of the anterior cortical implant distance on the lateral radiograph to ensure space for safe nail passage. We will also discuss intraoperative technical tricks, including Kirschner wire insertion for sounding the start point, utilization of the curved awl, use of hand reamers, and rotation of the nail to bypass the implant. Using meticulous preoperative planning and technical intraoperative tricks, patients with tibial shaft fractures below TKA may be successfully treated with intramedullary nailing.
Databáze: OpenAIRE