Popis: Oral rehabilitation success depends upon the accuracy and dimensional stability of the impressions. The purpose of this study is to evaluate the dimensional changes of a first impression type VPS (Vinyl Polysiloxane) (Imprint&trade
4 Preliminary Penta&trade
Super Quick, 3M ESPE&trade
St Paul, MN, USA). 10 samples were obtained from this silicone with an automatic mixing machine (Pentamix 2, 3M ESPE&trade
Seefeld, Germany) according to International Organization for Standardization (ISO) 4823:2000 and stored in the IPQ (Portuguese Institute for Quality) for one week. The measurements were performed by laser interferometry, according to the Michelson technique. The dimensional stability was calculated according to the formula specified in ISO (International Organization for Standardization) 4823:2000. A statistical analysis via a one-way repeated measures ANOVA was performed. The material shrinkage was 0.29 ±
0.15% after setting, 0.32 ±
0.21% at 24 h and 0.30 ±
0.23% after 1 week. No significant shrinkage of the silicone under investigation was found over time. This material can be stored for a week without the risk of clinically significant dimensional changes.