The response of a bonner sphere spectrometer to charged hadrons
Autor: | E. Dimovasili, Stefano Agosteo, Marco Silari, Alberto Fasso |
---|---|
Rok vydání: | 2004 |
Předmět: |
Health Physics and Radiation Effects
Proton Nuclear Theory Transducers Radiation Dosage Sensitivity and Specificity Nuclear physics Neutron detection Radiology Nuclear Medicine and imaging Neutron Computer Simulation Nuclear Experiment Radiometry Physics Bonner sphere Neutrons Radiation Models Statistical Radiological and Ultrasound Technology Spectrometer Spectrum Analysis Public Health Environmental and Occupational Health Reproducibility of Results General Medicine Equipment Design Neutron temperature Neutron spectroscopy Equipment Failure Analysis Neutron moderator Elementary Particles |
Zdroj: | Radiation protection dosimetry. 110(1-4) |
ISSN: | 0144-8420 |
Popis: | Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutrons above 10 MeV. These additional detectors employ a shell of material with a high mass number (such as lead) within the polyethylene moderator, in order to slow down high-energy neutrons via (n, xn) reactions. A BSS can be used to measure neutron spectra both outside accelerator shielding and from an unshielded target. Measurements were recently performed at CERN of the neutron yield and spectral fluence at various angles from unshielded, semithick copper, silver and lead targets, bombarded by a mixed proton/pion beam with 40 GeV per c momentum. These experiments have provided evidence that under certain circumstances, the use of lead-enriched moderators may present a problem: these detectors were found to have a significant response to the charged hadron component accompanying the neutrons emitted from the target. Conventional polyethylene moderators show a similar behaviour but less pronounced. These secondary hadrons interact with the moderator and generate neutrons, which are in turn detected by the counter. To investigate this effect and determine a correction factor to be applied to the unfolding procedure, a series of Monte Carlo simulations were performed with the FLUKA code. These simulations aimed at determining the response of the BSS to charged hadrons under the specific experimental situation. Following these results, a complete response matrix of the extended BSS to charged pions and protons was calculated with FLUKA. An experimental verification was carried out with a 120 GeV per c hadron beam at the CERF facility at CERN. |
Databáze: | OpenAIRE |
Externí odkaz: |