Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander
Autor: | Xiaoping Shen, Liu Ning, Liu Siling, Lei Lei, Yuhong He, Yanqin Lu, Ousheng Liu, Wang Xiao |
---|---|
Rok vydání: | 2021 |
Předmět: |
Nasal cavity
Article Subject QH301-705.5 Biomedical Engineering Medicine (miscellaneous) Bioengineering Nasal airway 03 medical and health sciences 0302 clinical medicine medicine Effective treatment Biology (General) Respiratory system 030223 otorhinolaryngology Alternative methods business.industry 030206 dentistry Nasal pressure medicine.anatomical_structure Anesthesia Breathing business TP248.13-248.65 After treatment Research Article Biotechnology |
Zdroj: | Applied Bionics and Biomechanics, Vol 2021 (2021) Applied Bionics and Biomechanics |
ISSN: | 1754-2103 1176-2322 |
DOI: | 10.1155/2021/8874833 |
Popis: | The use of the C-expander is an effective treatment modality for maxillary skeletal deficiencies which can cause ailments and significantly reduce life expectancy in late adolescents and young adults. However, the morphological and dynamic effects on the nasal airway have not been reported. The main goal of this study was to evaluate the nasal airway changes after the implementation of a C-expander. A sample of nine patients (8 females, 1 male, age range from 15 to 29 years) was included. The morphology parameters and nasal airway ventilation parameters of pretreatment and posttreatment were measured. All study data were normally distributed. A paired t -test was used to evaluate the changes before and after treatment. After expansion, the mean and standard deviation values of intercanine maxillary width (CMW) and intermolar maxillary width (MMW) increased from 35.75 ± 2.48 mm and 54.20 ± 3.17 mm to 37.87 ± 2.26 mm ( P < 0.05 ) and 56.65 ± 3.10 mm ( P < 0.05 ), respectively. The nasal cavity volume increased from 20320.00 ± 3468.25 mm3 to 23134.70 ± 3918.84 mm3 ( P < 0.05 ). The nasal pressure drop decreased from 36.34 ± 3.99 Pa to 30.70 ± 3.17 Pa ( P < 0.05 ), while the value of the maximum velocity decreased from 6.50 ± 0.31 m/s to 5.85 ± 0.37 m/s ( P < 0.05 ). Nasal resistance dropped remarkably from 0.16 ± 0.14 Pa/ml/s to 0.08 ± 0.06 Pa/ml/s ( P < 0.05 ). The use of C-expander can effectively broaden the area and volume of the nasal airway, having a positive effect in the reduction of nasal resistance and improvement of nasal airway ventilation. For patients suffering from maxillary width deficiency and respiratory disorders, a C-expander may be an alternative method to treat the disease. |
Databáze: | OpenAIRE |
Externí odkaz: |