Análise da timpanometria de banda larga na doença de Ménière
Autor: | Gisela Andrea Yamashita Tanno, Alessandra Spada Durante, Marcella Gameiro, Marcelo Tabosa Dutra Sanches, Nayara Michelle Costa de Freitas Roque, Kátia de Almeida, Mônica Alcantara de Oliveira Santos, Osmar Mesquita de Sousa Neto |
---|---|
Rok vydání: | 2022 |
Předmět: |
medicine.medical_specialty
Timpanometria Auditory tests Audiology Asymptomatic Doença de Ménière Tympanometry otorhinolaryngologic diseases Humans Medicine Endolymphatic Hydrops Inner ear Endolymphatic hydrops Meniere’s disease Meniere Disease Ossicular chain Acoustic impedance tests medicine.diagnostic_test business.industry Testes de impedância acústica medicine.disease Cross-Sectional Studies medicine.anatomical_structure Acoustic Impedance Tests Otorhinolaryngology Tympanometry Test Ear Inner Middle ear Testes auditivos sense organs medicine.symptom business Meniere's disease |
Zdroj: | Brazilian Journal of Otorhinolaryngology v.88 n.2 2022 Brazilian Journal of Otorhinolaryngology Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF) instacron:ABORL-CCF Brazilian Journal of Otorhinolaryngology, Volume: 88, Issue: 2, Pages: 194-203, Published: 03 JUN 2022 |
ISSN: | 1808-8694 |
Popis: | Introduction: Endolymphatic hydrops is the pathophysiological substrate of Ménière’s disease. The changes in the inner ear, transmitted to the middle ear through changes in the ossicular chain mobility, can be quantified by wideband tympanometry, through the measurement of the acoustic absorbance at multiple frequencies, represented by the sound energy absorbed by the middle ear, even at its early stages. Studying the behavior of the middle ear through the absorbance in patients with endolymphatic hydrops under ambient pressure and under peak pressure can be useful for detecting Ménière’s disease. Objective: To characterize acoustic absorbance behavior in subjects with symptomatic and asymptomatic Ménière’s disease compared to controls, in order to verify the ability of wideband tympanometry to detect Ménière’s disease. Methods: We carried out a cross-sectional study with a diagnostic approach comparing the findings of wideband tympanometry at ambient pressure and peak pressure between the ears of the control group (n = 30), the asymptomatic group (n = 21) and the symptomatic group (n = 9). Results: Different peak pressure values were found between the ears of the control group (0daPa), the asymptomatic group (−11 daPa) and the symptomatic group (−192 daPa), with p < 0.05 by the Kruskal-Wallis test, Mann Whitney test and Bonferroni correction. Different absorbance values were found between the ears of the symptomatic group and the asymptomatic group compared to the control group for low frequencies at ambient pressure and peak pressure, with p < 0.05 by the Kruskal-Wallis test, Mann Whitney test and Bonferroni correction. Conclusions: The Wideband Tympanometry test was capable of identifying the presence of Ménières disease, and to differentiate between asymptomatic and symptomatic patients, when comparing them with healthy individuals. Resumo Introdução: A hidropsia endolinfática é o substrato fisiopatológico da doença de Ménière. As alterações desencadeadas na orelha interna, transmitidas à orelha média pelas modificações na mobilidade da cadeia ossicular, podem ser quantificadas pela timpanometria de banda larga, através da medida da absorvância acústica sob múltiplas frequências, representadas pela energia sonora absorvida pela orelha média, mesmo em estágios iniciais de sua instalação. Estudar o comportamento da orelha média através da absorvância em pacientes com hidropisia endolinfática sob pressão ambiente e sob o pico de pressão pode ser útil na detecção da doença de Ménière. Objetivo: Caracterizar o comportamento da absorvância em indivíduos com diagnóstico da doença de Ménière sintomáticos e assintomáticos, comparados com controles, a fim de verificar a capacidade da timpanometria de banda larga em detectar variações clínicas relacionadas a possível hidropisia endolinfática. Método: Foi realizado um estudo transversal, com enfoque diagnóstico, que comparou os achados da timpanometria de banda larga na pressão ambiente e no pico de pressão entre orelhas do grupo controle (n = 30), grupo assintomático (n = 21) e grupo sintomático (n = 9). Resultados: Foram encontrados valores do pico de pressão diferentes entre orelhas do grupo controle (0 daPa), do grupo assintomático (-11 daPa) e do grupo sintomático (-192 daPa), com p |
Databáze: | OpenAIRE |
Externí odkaz: |