Conceptual Design of the Transverse Multi-Bunch Feedback for the Synchrotron Radiation Source PETRA IV

Autor: Jabłoński, Szymon, Duhme, Hans Thomas, Dursun, Burak, Klute, Jens, Mirza, Sajjad Hussain, Pfeiffer, Sven, Schlarb, Holger
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Geneva, Switzerland : JACoW Publishing 488-491 (2022). doi:10.18429/JACoW-IBIC2022-WEP36
[Ebook] IBIC 2022, International Beam Instrumentation Conference : 11-15 September 2022, Krakow, Poland : IBIC2022-proceedings / Organizers: GSI [Helmholtzzentrum für Schwerionenforschung]; SOLARIS, National Synchrotron Radiation Centre, Jagiellonian University in Krakow, [Geneva, Switzerland] : JACoW Publishing, [2022]
[Ebook] IBIC 2022, International Beam Instrumentation Conference : 11-15 September 2022, Krakow, Poland : IBIC2022-proceedings / Organizers: GSI [Helmholtzzentrum für Schwerionenforschung]; SOLARIS, National Synchrotron Radiation Centre, Jagiellonian University in Krakow, [Geneva, Switzerland] : JACoW Publishing, [2022],11th International Beam Instrumentation Conference, IBIC2022, Cracow, Poland, 2022-09-11-2022-09-15
DOI: 10.18429/jacow-ibic2022-wep36
Popis: [Ebook] IBIC 2022, International Beam Instrumentation Conference : 11-15 September 2022, Krakow, Poland : IBIC2022 - proceedings / Organizers: GSI [Helmholtzzentrum für Schwerionenforschung]; SOLARIS, National Synchrotron Radiation Centre, Jagiellonian University in Krakow , [Geneva, Switzerland] : JACoW Publishing, [2022], 11th International Beam Instrumentation Conference, IBIC 2022, Cracow, Poland, 11 Sep 2022 - 15 Sep 2022; Geneva, Switzerland : JACoW Publishing 488-491 (2022). doi:10.18429/JACoW-IBIC2022-WEP36
PETRA IV will be a new, fourth-generation, high-brilliance synchrotron radiation source in the hard X-ray range. To keep the emittance low at high beam current an active feedback system to damp transverse multi-bunch instabilities is required. The particular challenge to the system is the very low-noise, while maintaining high bandwidth, which is defined by the 2 ns bunch spacing. In this paper, we present the conceptual design of the transverse multi-bunch feedback (T-MBFB) system and technical challenges to fulfill the performance require-ments. An overview is given on the hardware and the method for detecting and damping the coupled-bunch oscillations. Using modern high-speed ADCs enables direct sampling of pulses from beam pick-ups, which removes the necessity for down-converters. Powerful digital signal processing allows not only for the effective feedback implementation, but also for developing versa-tile tools for the machine diagnostics.
Published by JACoW Publishing, Geneva, Switzerland
Databáze: OpenAIRE