The Multi-center Evaluation of the Accuracy of the Contrast MEdium INduced Pd/Pa RaTiO in Predicting FFR (MEMENTOFFR) Study

Autor: Antonio Maria Leone, Mariana Faustino, Luís Raposo, José M. de la Torre Hernández, Giuseppe Zimbardo, Eloisa Basile, Cristina Aurigemma, Francesco Burzotta, Giampaolo Niccoli, Antonio Giuseppe Rebuzzi, Nicolas Amabile, Vincent Spagnoli, Ramón López Palop, Sérgio Bravo Baptista, Filippo Crea, Pedro Farto e Abreu, Miren Telleria Arrieta, Italo Porto, Juan Antonio Franco Pelaez, Michel S. Slama, Carlo Trani, Pio Cialdella, Ignacio J. Amat Santos, Roberto Martín-Reyes
Jazyk: angličtina
Rok vydání: 2016
Předmět:
Male
contrast mediuminduced Pd/Pa
Contrast Media
CFFR
Coronary stenosis
Fractional flow reserve
030204 cardiovascular system & hematology
contrast FFR
FFR
03 medical and health sciences
Hyperaemia
0302 clinical medicine
medicine
Humans
cFFR
Contrast FFR
Contrast mediuminduced Pd/Pa ratio
Cardiology and Cardiovascular Medicine
030212 general & internal medicine
fractional flow reserve
Aged
Retrospective Studies
contrast medium-induced Pd/Pa ration
business.industry
Contrast media
Curve analysis
Coronary Stenosis
Limiting
rati
Middle Aged
Hybrid approach
Fractional Flow Reserve
Myocardial

Contrast medium
Settore MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE
Functional significance
Female
cFFR
contrast FFR
contrast mediuminduced Pd/Pa
rati
FFR
fractional flow reserve

medicine.symptom
business
Nuclear medicine
Zdroj: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Agência para a Sociedade do Conhecimento (UMIC)-FCT-Sociedade da Informação
instacron:RCAAP
EuroIntervention
r-FISABIO. Repositorio Institucional de Producción Científica
instname
r-FISABIO: Repositorio Institucional de Producción Científica
Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (FISABIO)
ISSN: 1774-024X
Popis: AIMS: Adenosine administration is needed for the achievement of maximal hyperaemia fractional flow reserve (FFR) assessment. The objective was to test the accuracy of Pd/Pa ratio registered during submaximal hyperaemia induced by non-ionic contrast medium (contrast FFR [cFFR]) in predicting FFR and comparing it to the performance of resting Pd/Pa in a collaborative registry of 926 patients enrolled in 10 hospitals from four European countries (Italy, Spain, France and Portugal). METHODS AND RESULTS: Resting Pd/Pa, cFFR and FFR were measured in 1,026 coronary stenoses functionally evaluated using commercially available pressure wires. cFFR was obtained after intracoronary injection of contrast medium, while FFR was measured after administration of adenosine. Resting Pd/Pa and cFFR were significantly higher than FFR (0.93±0.05 vs. 0.87±0.08 vs. 0.84±0.08, p
Databáze: OpenAIRE