A new liver functional study using Tc-99m DTPA-galactosyl human serum albumin: Evaluation of the validity of several functional parameters

Autor: Takao Ainoda, Yoshioki Yoda, Takao Arai, Kiyoshi Koizumi, Guio Uchiyama
Rok vydání: 1992
Předmět:
Zdroj: Annals of Nuclear Medicine. 6:83-87
ISSN: 1864-6433
0914-7187
DOI: 10.1007/bf03164647
Popis: Several parameters calculated with a new functional imaging agent for the liver, Tc-99m DTPA-galactosyl human serum albumin, were evaluated in 9 patients with liver cirrhosis, one with hepatocellular carcinoma, and five with both liver cirrhosis and hepatocellular carcinoma. LU3, which represents the cumulative uptake of the tracer from 3 to 4 minutes after injection, showed a strong correlation (r = 0.858, p = 0.0001) with LHL15, which represents the count ratio for the liver to sum for the liver and heart 15 minutes after injection of the tracer. It also showed a strong correlation (r = -0.896, p = 0.0001) with the indocyanine green retention rate (ICGR15). Regional ICGR15 is therefore calculable from the regional LU3. GSAR15, which represents the radioactivity of the tracer retained in the blood 15 minutes after injection, showed a strong correlation (r = 0.878, p = 0.0001) with HH15, which represents the count ratio for the heart 15 minutes after injection of the tracer divided by the count for the heart 3 minutes after injection. In conclusion, LU3 and GSAR15 are interesting and promising parameters for assessing liver function.