lcsh:QH471-489 Visual analogue scale Intrauterine device Perceived pain law.invention 03 medical and health sciences 0302 clinical medicine Randomized controlled trial law lcsh:Reproduction Medicine Pain perception Clinical significance 030212 general & internal medicine Cervix Vas score lcsh:R5-920 030219 obstetrics & reproductive medicine business.industry Obstetrics and Gynecology Surgery medicine.anatomical_structure Reproductive Medicine lcsh:Medicine (General) business |
Zdroj: | Middle East Fertility Society Journal, Vol 23, Iss 2, Pp 143-147 (2018) |
ISSN: | 1110-5690 |
DOI: | 10.1016/j.mefs.2017.09.011 |
Popis: | Objective: The study aims to investigate the effect of slow versus fast vulsellum application on the cervix on the perceived pain during copper intrauterine device (IUD) insertion. Study design: We conducted a randomized controlled trial at a tertiary university hospital from October 2016 to May 2017 included women desiring copper IUD insertion. We randomized the participants in a 1:1 ratio to slow and fast vulsellum application during IUD insertion. The primary outcome measure was the subjects’ self-reported pain using a 100 mm Visual Analogue Scale (VAS) during cervical tenaculum placement. We considered a 20 mm difference in VAS scores as clinically significant. The secondary outcomes included the difference in pain scores during IUD insertion and five minutes after insertion, the amount and duration of vulsellum site bleeding. Results: The study included 200 women (n = 100 in each group). Women in the slow vulsellum group had significant lower pain scores during tenaculum placement, IUD insertion and 5 min post-insertion (p = .0001). However, the difference in pain scores did not show a clinical significance. The duration needed to control the bleeding in fast vulsellum group was 2.34 min versus 1.87 min in the slow vulsellum group (p = .006). Additionally, the VAS score for the amount of bleeding was significantly higher in the fast than the slow vulsellum group (2.83 ± 1.38 vs. 1.97 ± 1.45. p = .008). Conclusions: Slow vulsellum application could reduce the pain scores during IUD insertion as compared with fast vulsellum application. Moreover, it is associated with less amount and duration of bleeding from the vulsellum puncture sites. Keywords: Intrauterine device, Vulsellum, Pain relief |
Databáze: | OpenAIRE |
Externí odkaz: |