The backwards comparability of wrist worn GENEActiv and waist worn ActiGraph accelerometer estimates of sedentary time in children
Autor: | Zoe R. Knowles, Liezel Hurter, Alex V. Rowlands, Robert J. Noonan, Stuart J. Fairclough, Lynne M. Boddy |
---|---|
Přispěvatelé: | Boddy, Lynne M, Noonan, Robert J, Rowlands, Alex V, Hurter, Liezel, Knowles, Zoe R, Fairclough, Stuart J |
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Male
Waist Intraclass correlation vhildren RJ101 physical activity Physical Therapy Sports Therapy and Rehabilitation Wrist Accelerometer Sensitivity and Specificity RC1200 03 medical and health sciences Wearable Electronic Devices 0302 clinical medicine Cronbach's alpha Statistics Abdomen Accelerometry sedentary behaviour medicine accelerometry Humans Orthopedics and Sports Medicine 030212 general & internal medicine Child Group level Mathematics Sedentary time Reproducibility of Results 030229 sport sciences raw acceleration signals medicine.anatomical_structure Cross-Sectional Studies Female measurement Sedentary Behavior Kappa |
Zdroj: | JOURNAL OF SCIENCE AND MEDICINE IN SPORT |
ISSN: | 1440-2440 |
Popis: | Objectives: To examine the backward comparability of a range of wrist-worn accelerometer estimates of sedentary time (ST) with ActiGraph 100 count min −1 waist ST estimates. Design: Cross-sectional, secondary data analysis Methods: One hundred and eight 10–11-year-old children (65 girls) wore an ActiGraph GT3X+ accelerometer (AG) on their waist and a GENEActiv accelerometer (GA) on their non-dominant wrist for seven days. GA ST data were classified using a range of thresholds from 23 to 56 mg ST estimates were compared to AG ST 100 count min −1 data. Agreement between the AG and GA thresholds was examined using Cronbach's alpha, intraclass correlation coefficients (ICC), limits of agreement (LOA), Kappa values, percent agreement, mean absolute percent error (MAPE) and equivalency analysis. Results: Mean AG total ST was 492.4 min over the measurement period. Kappa values ranged from 0.31 to 0.39. Percent agreement ranged from 68 to 69.9%. Cronbach's alpha values ranged from 0.88 to 0.93. ICCs ranged from 0.59 to 0.86. LOA were wide for all comparisons. Only the 34 mg threshold produced estimates that were equivalent at the group level to the AG ST 100 count min −1 data though sensitivity and specificity values of ∼64% and ∼74% respectively were observed. Conclusions: Wrist-based estimates of ST generated using the 34 mg threshold are comparable with those derived from the AG waist mounted 100 count min −1 threshold at the group level. The 34 mg threshold could be applied to allow group-level comparisons of ST with evidence generated using the ActiGraph 100 count min −1 method though it is important to consider the observed sensitivity and specificity results when interpreting findings Refereed/Peer-reviewed |
Databáze: | OpenAIRE |
Externí odkaz: |