Mass Spectrometric Calibration Procedure for Real-Time Detection of Lighter Hydrocarbons
Autor: | Puspa L. Adhikari, Makuachukwu F. Mbaegbu, Mathew Rowe, Ipsita Gupta |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Analyte
Control and Optimization Materials science Analytical chemistry Energy Engineering and Power Technology 010501 environmental sciences Mass spectrometry lcsh:Technology 01 natural sciences chemistry.chemical_compound Propane fragmentation base peaks Calibration Electrical and Electronic Engineering Engineering (miscellaneous) Quadrupole mass analyzer 0105 earth and related environmental sciences chemistry.chemical_classification lcsh:T Renewable Energy Sustainability and the Environment 010401 analytical chemistry lighter hydrocarbons Butane 0104 chemical sciences Pentane Hydrocarbon chemistry Energy (miscellaneous) mass spectrometric calibration |
Zdroj: | Energies Volume 14 Issue 8 Energies, Vol 14, Iss 2123, p 2123 (2021) |
ISSN: | 1996-1073 |
DOI: | 10.3390/en14082123 |
Popis: | Determining gas compositions from live well fluids on a drilling rig is critical for real time formation evaluation. Development and utilization of a reliable mass spectrometric method to accurately characterize these live well fluids are always challenging due to lack of a robust and effectively selective instrument and procedure. The methods currently utilized need better calibration for the characterization of light hydrocarbons (C1–C6) at lower concentrations. The primary goal of this research is to develop and optimize a powerful and reliable analytical method to characterize live well fluid using a quadruple mass spectrometer (MS). The mass spectrometers currently being used in the field have issues with detection, spectra deconvolution, and quantification of analytes at lower concentrations (10–500 ppm), particularly for the lighter (< 30 m/z) hydrocarbons. The objectives of the present study are thus to identify the detection issues, develop and optimize a better method, calibrate and QA/QC the MS, and validate the MS method in lab settings. In this study, we used two mass spectrometers to develop a selective and precise method to quantitatively analyze low level lighter analytes (C1–C6 hydrocarbons) with masses < 75 m/z at concentrations 10–500 ppm. Our results suggest that proper mass selection like using base peaks with m/z 15, 26, 41, 43, 73, and 87, respectively, for methane, ethane, propane, butane, pentane, and hexane can help detect and accurately quantify hydrocarbons from gas streams. This optimized method in quadrupole mass spectrometer (QMS) will be invaluable for early characterization of the fluid components from a live hydrocarbon well in the field in real time. |
Databáze: | OpenAIRE |
Externí odkaz: |