Comparison of Materials used in Facilitating External Cephalic Version

Autor: Saana Bibji, Nargis Shabana, Shamsa Tariq, Khair Un Nisa, Faiza Safdar, Noreen Majeed
Rok vydání: 2022
Zdroj: Journal of Rawalpindi Medical College. 26:271-275
ISSN: 1683-3570
1683-3562
DOI: 10.37939/jrmc.v26i2.1847
Popis: Introduction: External cephalic version (ECV) is a procedure to manipulate a fetus with breech presentation to cephalic presentation through maternal abdomen under ultrasound guidance. It is done to reduce the number of assisted breech deliveries and caesarean sections for breech presentation. Talcum powder or aqueous gel is frequently used to facilitate ECV. We compared powder with gel in attaining a successful version and level of practitioner satisfaction with powder versus gel use.Materials and Methods: This retrospective descriptive study was conducted by Wah Medical College in POF hospital (affiliated with WMC) , Wah Cantt from 10th Oct 2015- 10th Oct 2019. Total of 56 low risk gravid women underwent ECV after selection on the basis of inclusion and exclusion criteria. By using convenient consecutive sampling, powder or gel during ECV was allocated accordingly. ECV was performed by the single experienced practitioner in labour room with cardiotocograph and emergency caesarean facilities . Powder and gel use was compared in attaining a successful version. ECV was declared successful on confirming head of fetus in lower uterine segment on ultrasound. Unsuccessful ECVs were reattempted with crossover use to the other aid. Practitioner satisfaction was defined as, ease experienced by the practitioner in performing ECV. It was graded as high, medium and low on the base of ease or difficulty experienced by the practitioner while using powder or gel during ECV. The data was recorded & analysed using SPSS software. Descriptive statistics with Chi-square test is applied to find out the association between successful version & practitioner satisfaction level with powder versus gel use.Results: In the powder use group, 9 ECVs were successful and 19 ECV’s were unsuccessful. In gel use group, 12 ECVs were successful and 16 were unsuccessful. There were more successful ECV’s in gel group but the association was not significant (P-value .408). Practitioner satisfaction was significantly high with gel than the powder use(P-value .
Databáze: OpenAIRE