Measure by Measure: Resting Heart Rate Across the 24 Hour Cycle

Autor: Tom Arneil, Justin P Phillips, Michael V. McConnell, Alex Wilson, Cathy A Speed, Robert Keith Harle, Alan Karthikesalingam
Rok vydání: 2021
Předmět:
DOI: 10.1101/2021.11.24.21266320
Popis: BackgroundPhotoplethysmography (PPG) sensors, typically found in wrist-worn devices, can continuously monitor heart rate (HR) in large populations in real-world settings. Resting heart rate (RHR) is an important biomarker of morbidities and mortality, but no universally accepted definition nor measurement criteria exist. In this study, we provide a working definition of RHR and describe a method for accurate measurement of this biomarker, recorded using PPG derived from wristband measurement across a 24 hour cycle. Methods433 healthy subjects wore a wrist device that measured activity and HR for up to 3 months. HR during inactivity was recorded and the duration of inactivity needed for HR to stabilise was ascertained. We identified the lowest HR during each 24-hour cycle (true RHR) and examined the time of day or night this occurred. The variation of HR during inactivity through the 24-hour cycle was also assessed. The sample was also subdivided according to daily activity levels for subset analysis. FindingsAdequate data was obtained for 19,242 days and 18,520 nights. HR stabilised in most subjects after 4 minutes of inactivity. Mean (SD) RHR for the sample was 54.5 (8.0) bpm (day) and 50.5 (7.6) bpm (night). RHR values were highest in the least active group (lowest MET quartile). A circadian variation of HR during inactivity was confirmed, with the lowest values being between 0300 and 0700 hours for most subjects. InterpretationRHR measured using a PPG-based wrist-worn device is significantly lower at night than in the day, and a circadian rhythm of HR during inactivity was confirmed. Since RHR is such an important health metric, clarity on the definition and measurement methodology used is important. A minimum rest time of 4 minutes provides a reliable measurement of HR during inactivity and true RHR in a 24-hour cycle is best measured between 0300 and 0700 hours. FundingThis study was funded by Google. O_TEXTBOXResearch In contextResting heart rate is one of the most fundamental and relevant biomarkers in health and disease. Its measurement, particularly in large population studies, is increasingly reliant on sensor devices. No universally accepted definition nor measurement criteria exist. In this study, we provide a working definition of RHR and describe a method for measurement of RHR recorded using PPG derived from wristband measurement. We make recommendations to support future studies of resting heart rate using wearable sensors. C_TEXTBOX
Databáze: OpenAIRE