Control Strategy of Single-Phase Active Front-End Cascaded H-Bridge Under Cell Fault Condition

Autor: Seung-Ki Sul, Jeong-Mock Yoo, Hyun-Sam Jung, Yoon-Ro Lee
Rok vydání: 2019
Předmět:
Zdroj: IEEE Transactions on Power Electronics. 34:4780-4793
ISSN: 1941-0107
0885-8993
DOI: 10.1109/tpel.2018.2858009
Popis: Cascaded H-bridge (CHB) inverter is the most widely used topology for a medium-voltage drive system due to the high degree of modularity, easier implementation of medium output voltage, and the ability to continuous operation under the cell fault condition. Because each power cell of CHB should have isolated dc source, multiwinding input transformer and three-phase active front end (AFE) are generally used for regenerative applications. The whole system can be simplified by replacing the three-phase AFE with single-phase AFE. However, if the control strategy of normal operation is adopted under the cell fault condition, input power imbalance among three phases inevitably occurs. In that situation, not only faulty cells, but also some unscathed cells should be excluded with giving up the maximum capability of the system, not to deteriorate grid current. This paper proposes a control scheme against the cell fault condition of the single-phase AFE CHB. By applying the proposed control scheme to the system, dc-link voltage of each cell and grid current are well regulated without imbalance even under the cell fault conditions. Finally, it can minimize the number of undamaged cells which should be turned off and maximize the capability of the system under the cell fault condition. Simulation and experimental results are provided to verify the effectiveness of the proposed scheme.
Databáze: OpenAIRE