Biomechanical Comparison of Anterior Cruciate Ligament Reconstruction Using a Single-Bundle Round or Ribbon-like Hamstring Tendon Graft
Autor: | Jean-Romain Delaloye, Christoph Hartog, Samuel Blatter, Michel Schläppi, Dominic Müller, Thorsten Schwenke, Jozef Murar, Peter P. Koch |
---|---|
Rok vydání: | 2023 |
Předmět: | |
Zdroj: | The American Journal of Sports Medicine. 51:1162-1170 |
ISSN: | 1552-3365 0363-5465 |
DOI: | 10.1177/03635465231159069 |
Popis: | Background: Persistent instability of the knee is reported in up to 30% of patients after anterior cruciate ligament (ACL) reconstruction. Based on anatomic findings showing that ACL is a flat ribbon-like structure that twists during knee flexion, a new surgical ACL reconstruction technique using a ribbon-like graft has been developed. However the effect of this surgical technique on knee kinematics has not yet been evaluated. Purpose: To compare the anteroposterior and rotational stability of the knee after ACL reconstruction using single-bundle (SB) round and ribbon-like grafts in anterolateral-intact/deficient knees. Study Design: Controlled laboratory study. Methods: Twelve human fresh-frozen cadaveric knees were tested with a 6 degrees of freedom robotic system. Internal rotation and anterior translation of the knee were recorded from 0° to 90° of flexion. A full kinematic assessment was performed in each of the following conditions: (1) intact knee, (2) after sectioning of the ACL, (3) after ACL reconstruction using a SB hamstring tendon graft in a round configuration and a ribbon-like configuration, and (4) after sectioning of the anterolateral structures. One-way analysis of variance and post hoc Tukey tests were used for statistical analyses. Results: When compared with the intact knee, the ACL-deficient knee demonstrated a mean ± SD increase in anterior translation and internal rotation of 6.3 ± 2.5 mm ( P < .01) and 5.8°± 2.3° ( P < .01), respectively. After ACL reconstruction using a SB ribbon-like graft, the mean difference in anterior translation and internal rotation as compared with the intact knee was −0.1 ± 1.5 mm ( P = .842) and 0.0°± 1.1° ( P = .999). These differences from the intact knee were also not significant after ACL reconstruction using a round graft (−0.1 ± 1.3 mm, P = .999; −0.5°± 1.5°, P = .401). In the ACL-reconstructed knee using either a ribbon-like or round graft, sectioning of the anterolateral structures did not induce a significant increase of anterior translation and internal rotation of the knee. Conclusion: ACL reconstruction using a SB ribbon-like or round graft restored the kinematics of the intact knee at time zero. Secondary sectioning of the anterolateral structures in the ACL-reconstructed knee using both types of graft did not significantly affect the anterior translation and internal rotation of the knee. Clinical Relevance: This is the first biomechanical study on the new ACL reconstruction technique using a ribbon-like graft. |
Databáze: | OpenAIRE |
Externí odkaz: |