Autor: |
Leonardo Calabrese, K.R. Williams, Arturo N. Natali, E. A. Meroi |
Rok vydání: |
1997 |
Předmět: |
|
Zdroj: |
Dental Materials. 13:325-332 |
ISSN: |
0109-5641 |
DOI: |
10.1016/s0109-5641(97)80103-0 |
Popis: |
Objectives The aim of this work was to present a preliminary numerical analysis of the integration process of dental implants using a finite element simulation of the dynamic response following impulse excitation. Assessment of the osseointegration process has been previously examined using a numerical approach by calculating the natural frequency of a cantilever attached to the implant. The methodology adopted in this work allows a direct measurement of the implant response following impulse loading and avoids the addition of a bulky cantilever set-up. Methods The geometric configuration was obtained by averaging the coordinate data from tomographic scans of 14 mandibles. The materials properties were approximated from experimental analysis performed on trabecular and cortical bone tissue. A load was applied to the top of the implant in one direction resulting in an initial displacement. The implant was then freed and allowed to vibrate over approximately 10 cycles. Three fixity conditions were assumed by changing the properties of the surrounding bone ranging from full integration to a poorly integrated implant typical of the situation during bone healing following surgery. The results of the three fixity conditions were compared by calculating the fundamental displacement amplitudes and frequencies of the vibrating impact. Results The calculated results indicated that the implant vibrated at a predominant frequency when partially integrated with a displacement principally in the direction of the applied impulse. However, when the implant was fully integrated a more complex vibration pattern ensued, suggesting the superposition of two or more fundamentals. Significance Attention has been paid to the formulation of the numerical model for validation purposes as well as a reliable reference for the optimum interpretation of the experimental data. In this way it was possible to establish a simulation procedure to investigate the response of the tissues surrounding the implant and their properties at different stages of healing. It should be pointed out that the numerical procedures represented a valid preliminary approach to the problem and were capable of indicating a guide to the optimum design of the experimental apparatus for measurement of displacement and frequency in vivo . |
Databáze: |
OpenAIRE |
Externí odkaz: |
|