Ion-Pair High-Performance Liquid Chromatographic Determination of Strychnine Alkaloid in an Animal Tissue
Autor: | Carol A. Furcolow, Bruce A. Kimball |
---|---|
Rok vydání: | 1995 |
Předmět: | |
Zdroj: | Journal of Agricultural and Food Chemistry. 43:700-703 |
ISSN: | 1520-5118 0021-8561 |
DOI: | 10.1021/jf00051a026 |
Popis: | A method for the determination of strychnine alkaloid residues in animal tissues using ion-pair reversed-phase high-performance liquid chromatography is described. Following treatment with triethylamine, strychnine was extracted from whole-ground northern pocket gopher tissue with n-butyl chloride. The extraction solvent was evaporated and the sample reconstituted in the liquid chromatographic mobile phase containing the ion-pairing reagent heptanesulfonic acid. This method enables better than 80% strychnine recovery from tissue samples fortified with strychnine at concentrations ranging from 0.2 to 50 μg/g. Excellent precision is also obtained as demonstrated by standard deviations of replicate analyses of approximately 5%. The method limit of detection was 100 ng of strychnine/g of sample |
Databáze: | OpenAIRE |