The Organization of a JINR Proton Synchrotron Beami Slow Extraction Parameter Monitoring and Contrzol System in the CAMAC Standard on-Line with an US1010 Computer
Autor: | Nguen Viet Zung, V.I. Volkov, V. A. Smirnov, L. G. Efimov, E. V. Chernykh, I.I. Kulikov |
---|---|
Rok vydání: | 1977 |
Předmět: |
Nuclear and High Energy Physics
Engineering business.industry Nuclear engineering Interface (computing) Electrical engineering Condition monitoring Proton Synchrotron Feedback loop Line (electrical engineering) Nuclear Energy and Engineering Control system Physics::Accelerator Physics Electrical and Electronic Engineering business Beam (structure) Computer Automated Measurement and Control |
Zdroj: | IEEE Transactions on Nuclear Science. 24:2561-2565 |
ISSN: | 0018-9499 |
Popis: | A general view of the CAMAC proton synchrotron slow extraction (SE) beam parameter monitoring and control system on-line with an US1010 computer is given. CAMAC provides an interface between the computer and transducers, as well as between the remote controlled SE devices, by means of a universal branch driver developed and used at the High Energy Laboratory as a standard interface for large CAMAC installations. The system is used to measure some parameters of the accelerator, which deter mine the operating made of slow extraction, of a slow extraction system and of an ejected beam. The system includes a closed feedback loop for making corrections in order to stabilize the ejected beam and to optimize the operation of the slow extraction system. |