Development of a membrane integrity monitoring strategy for the UF/RO Heemskerk drinking water treatment plant

Autor: S.C.J.M. van Hoof, P.C. Kamp, H.C. Folmer, M.M. Nederlof, Joop C. Kruithof
Rok vydání: 2001
Předmět:
Zdroj: Water Supply. 1:261-271
ISSN: 1607-0798
1606-9749
Popis: At the Heemskerk water treatment plant of N.V. PWN Water Supply Company North Holland the first full scale integrated membrane system in the Netherlands is realized. The 20 Mm3/year (15 MGD) ultrafiltration (UF)/reverse osmosis (RO) plant servicing IJssel Lake water has been in operation since the second half of 1999. Disinfection is a major objective of the direct surface water treatment plant without chemical disinfection. After UF indicator organisms such as E. coli and Clostridia spores were absent. Integer UF membranes removed MS-2 phage spikes completely (
Databáze: OpenAIRE