Popis: | At the Heemskerk water treatment plant of N.V. PWN Water Supply Company North Holland the first full scale integrated membrane system in the Netherlands is realized. The 20 Mm3/year (15 MGD) ultrafiltration (UF)/reverse osmosis (RO) plant servicing IJssel Lake water has been in operation since the second half of 1999. Disinfection is a major objective of the direct surface water treatment plant without chemical disinfection. After UF indicator organisms such as E. coli and Clostridia spores were absent. Integer UF membranes removed MS-2 phage spikes completely ( |